background image

  

 

Service 

 

 

 

 

[ S ]  41 

 

Fire Alarm

 

A temperature sensor indicates a temperature of above 80°C. 

The device will power down and close air flaps. 

 

 

 

 

 

Control Error

 

The device will power down and close air flaps.  

Red LED is illuminated 

– yellow LED will flash: 

By pushing the 

-Button the following described error causes 

are indicated. 

 

 

 

 

  

Note

 

Error messages will be erased by switching the device off and back on at the main power 

switch. 

 

Piep 
Piep 
Piep 
Piep 
Piep 
Piep 

Summary of Contents for freeAir100

Page 1: ...all references to safety and use of the freeAir100 in part General G Device Test After correct installation turn the freeAir100 on and wait a few minutes while the device executes a test routine Test Turbo operation once either only blue LEDs or no LEDs are illuminated Connect Software For control of device functions and for any update we recommend Laptop Windows 7 or 8 USB cable A on B Our free s...

Page 2: ...freeAir100 from the wall box it is possible that some remaining condensate water will flow from the heat exchanger 2 Push the two metal flaps apart and remove the dirty supply filter Please only use original bluMartin filters Note For allergy sufferers are also filter class F7 available increased air resistance some more noise 3 Pull the extract filter out of the side of the device and replace wit...

Page 3: ...d in front and bottom and slide it straight into the box Slide by pressing the front panel on the unit until it stops Note The device will only be operational if seated completely inside the wall box if necessary beat with your hand on the front panel 6 To reset the filter hour counter shortly change into Service mode To do that turn first the device off Push and hold the button and switch the dev...

Page 4: ...oom Extract m3 h The additional 2nd Room Extract module enables adjustment of max air flow of ventilation for exhaust of the 2nd room Diameter length and number of turns in the ducting as well as air inlet size limit the air stream see table above off No exhaust ducting installed or extract opening blocked 30 One flex duct connected with extract valve 125 60 Two flex ducts installed with extract v...

Page 5: ...vailable in devices with a serial number of 2000 or higher Temperature is set to 22 C in older devices Room Area m2 Enter here the number of square meters to be ventilated Please factor in all connected rooms This input is the basis for minimum ventilation calculations Notes If you find the intermittent operation bothersome adjust the room area to less than 60 m2 at Comfort Level 1 or to less than...

Page 6: ...late onto the device don t damage cables Attach the included M3 screws for grounding of the front panel Then attach the front plate with 4 counter sunk 4 x 20 wood screws Note Please make sure to adjust the DIP switches first see above in this section DANGER A missing grounding screw in the front plate can cause injury or death by electrical shock ...

Page 7: ...etal sheet using two M3 raised head screws Notes The supply air outlet is designed to guide air into the room as far as possible Air direction can be changed by adjusting the air paddles Air outlets guiding air downward are available as an extra Filter Installation Attach the metal bracket for the inlet air filter using four 4x20 flat head screws ...

Page 8: ... Selecting the Service Operation will reset the filter hour counter to zero After switching the device off and back on all functions will be restored to Comfort or Dehumitification operation Prolonged holding of the Button will launch Test Operation the upper middle as well as the lower blue LEDs will be on In Service Operation some functions such as defrost are not available Therefore this operat...

Page 9: ...r both fans indicate an error because the air flow is restricted due to a dirty filter This error message can also be triggered by other air flow obstructions such as under dimensioned opening between supply and extract air DIP switch setting for extract air is set too high or simultaneous operation of a kitchen vent hood while windows are closed CO2 Content CO2 content is measured to be above 350...

Page 10: ...e air flaps Control Error The device will power down and close air flaps Red LED is illuminated yellow LED will flash By pushing the Button the following described error causes are indicated Note Error messages will be erased by switching the device off and back on at the main power switch Piep Piep Piep Piep Piep Piep ...

Page 11: ...ll be indicated 2 Push and hold Button 3 Cause of error display CO2 Sensor Temperature Sensor Outside Air Temperature Sensor Exhaust ______________________ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ ...

Page 12: ...error correction __ __ __ __ __ __ ______________________ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ ______________________ ______________________ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ __ __ __ __ __ __ ___________________...

Page 13: ...use as well as the freeAir100 serial number Note Returning the device has to be coordinated with your service partner The device has to be shipped using the appropriate packaging __ __ __ __ __ __ ______________________ __ __ __ __ __ __ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ ...

Page 14: ...jammed due to improper transportation Remove the extract filter and carefully push the blade wheel downward For the supply air fan loosen the 4 outer flat head screws and lift up the motor plate by 10mm Blue LEDs blinking continuously Service or Dehumidifying operation is active Service operation is activated by pushing and holding the Button while the device is switched on This can happen by acci...

Page 15: ...her a 2nd Room Extract connection had been selected even though the device is not equipped with one no 4th air flap and seal present Also check to see whether 1st room extract is deselected even though the 2nd Room Extract is not set to 100 m h ...

Page 16: ...oam body Note Take care not to reach into the fragile fins of the heat exchanger Transport and Storage Components of the freeAir100 must only be transported in the correct packaging The freeAir100 must be shipped on a pallet to protect it from shock The freeAir100 and packaging must be protected from moisture ...

Page 17: ...e Service Log Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Note Filter Run Time counter has to be reset ...

Page 18: ...re Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Date Signature Note Filter Run Time counter has to be reset ...

Reviews: