Alternative drilling
1)
Only on the left side
Cabinet height
Do not glue the Blum distance bumper
Cabinet height
Recommendation for aluminium frames: Consider drilling Blum distance
bumper into the cabinet side.
A trial application must be carried out when fixing the Blum distance bumper
to the front.
Planning information Prefered position for distribution cable (AVENTOS HF)
1)
Blum distance bumper
Blum distance bumper drilling position
For specific applications (low front
with high weight) several bumpers are
necessary.
Bumper must be installed near switch.
A trial application is recommended!
*
From cabinet front edge for fronts that protrude below
6
H
480–549 mm
KH x 0.3 - 28 mm
550–1.040 mm
KH x 0.3 - 57 mm
AVENTOS HF
AVENTOS HS / -HL
KH
AVENTOS HK
AVENTOS HF / -HS / -HL
AVENTOS HK