Safety

1.   Read carefully before usage.

2.   Only suitable for indoor use.

3.   Ensure voltage shown on the label match to the mains supply voltage.

4.   Never connect Polario to another cable or ballast then the one supplied, any misuse will void the warranty! 

5.   Mount controller and transformer on a dry space, away from moisture or water, there is no warranty on damages caused by water on water

controller or transformer!

6.   Never let the pump run dry, keep it submerged at all times.

7.   Unplug or switch off all appliances in the aquarium before carrying out maintenance.

8.   If damaged, the pump cord cannot be replaced, the whole unit needs to be recycled.

9.   This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of

experience and knowledge if they have been given supervision or instructions concerning the use of the appliance in a safe way and understand

the hazards involved. Children may not play with the appliance. Cleaning and user maintenance shall not be done by children without 

supervision.

Installation

1.   Rinse the pump and parts with clean tap water before installing.

2.   Choose the desired position for the magnet mount.

3.   Separate the magnet mount by twisting units apart.

4.   Place the pump in the desired location in the aquarium (page 3, step 1).

5.   Mount and secure the controller and transformer in an area that is dry, and will stay dry and away from the aquarium, see pictures page 3.

6.   Plug pump cable into the transformer.

7.   Now start the pump by plugging the cable, ensure cable drip loop (page 3, step 2).

Usage

1.   Polario offers Bi-directional water flow to simulate natural wave and currents of the ocean.

2.   The flow is pre-set and cannot be changed, see the specifications for the flow of your model! 

3.   After power on, water will flow from left at 50% power for 5 seconds, then 75% power for 5 seconds, then 100% power 

for 5 seconds, followed by 5 seconds break, then the same cycle will start on right side, this continues till power off;

Maintenance

1.   Monthly cleaning is needed to ensure proper operation! 

2.   Disconnect pump from mains before any maintenance on the aquarium.

3.   Remove pump from the tank and remove strainer.

4.   Remove the propeller, clean propeller and pump in a 50% vinegar, and 50% water-solution, soak it for at least 1 hour, clean with a

fine brush. Check that the propeller rotates freely on the shaft. In some cases, repeat cleaning and soaking can be needed to remove

all scale deposits.

5.   Re assemble pump and place it back into the aquarium.

6.   Make sure inlet strainer on both sides are always open and clean!

7.   The propeller is subject to wear, depending on the usage it needs replacement annually, this is normal maintenance is not covered by

the warranty. New propellers are available from your dealer.

Trouble shooting

1.   Controller will not power up and/or pump will not turn on.

2.   Most likely you have blown the fuse, make sure pump, rotor and strainer are clean!.

3.   The fuse will have to be replaced, turn off the unit and unplug the transformer, see picture on page 2; part list.

4.   Remove the back plate of the controller, take out fuse with flat head screwdriver and replace 

5.   Use 1.6 amp fuse for Polario 4000 and 2.5 amp fuse for Polario 10000, 1 spare fuse is included with each pump, additional spare

fuses are available at your dealer.

6.   Restart the unit, if the unit still not work return unit to your dealer for checking.

GB

Summary of Contents for Polario 4000

Page 1: ... Low voltage 360 degrees Energy saving 12V Item Polario 4000 Polario 10000 Watt 230V 50Hz 7W 25W Pump size L x Dia 4 8 x 5 cm 5 4 x 6 cm Flow Rate L h 2300 4000 6000 10000 Recommended Aquarium Size 30 150 Liter 150 400 Liter Polario ...

Page 2: ...er 5 4 x Gummispannbänder 6 360 Montagebügel 7 Magnetbefestigung 8 Sicherung 9 Controller 10 Trafo 11 Netzstecker F PARTIES 1 Crépine 2 Pompe 3 Axe Céramique 4 Propeller 5 4x silentbloc en caoutchouc 6 Support 360 degré 7 Aimant 8 Fusible 9 Controlleur 10 Ballast 11 Prise NL ONDERDELEN 1 Zeef 2 Pomphuis 3 Keramische As 4 Propeller 5 4x rubber spanners 6 360 montagebeugel 7 Magneet montage 8 Zekeri...

Page 3: ...données les cartes de crédit les équipements électroniques et les dispositifs médicaux NL Waarschuwing Zeer sterke magneet Buiten het bereik van kinderen houden indien dit niet gebeurt kan ernstig letsel of schade ontstaan Deze magneten zullen andere metalen of magneten met geweld aan te trekken weg houden van apparaten die gevoelig zijn voor magnetische velden zoals pacemakers gegevensdragers cre...

Page 4: ...ers Bi directional water flow to simulate natural wave and currents of the ocean 2 The flow is pre set and cannot be changed see the specifications for the flow of your model 3 After power on water will flow from left at 50 power for 5 seconds then 75 power for 5 seconds then 100 power for 5 seconds followed by 5 seconds break then the same cycle will start on right side this continues till power ...

Page 5: ...trömungen des Ozeans zu simulieren 2 Die Fördermenge ist voreingestellt und kann nicht geändert werden beachten Sie hierfür die technischen Angaben der entsprechenden Pumpe 3 Nach dem Einschalten strömt dasWasser für 5 Sekunden von links bei 50 Leistung aus der Pumpe dann mit 75 Leistung für 5 Sekunden dann mit 100 Leistung für 5 Sekunden gefolgt von 5 Sekunden Pause Danach startet der gleiche Zyk...

Page 6: ...ement page 3 étape 2 Utilisation 1 Polario propose un débit d eau bidirectionnel pour simuler une vague naturelle et les courants de l océan 2 Le flux est prédéfini et ne peut être modifié voir les spécifications pour le flux de votre modèle 3 Après la mise sous tension l eau ira de gauche à droite d abord à gauche à 50 de la puissance pendant 5 secondes puis 75 de la puissance pendant 5 secondes ...

Page 7: ...i directionele waterstroom om natuurlijke golven en stromingen van de oceaan te simuleren 2 De waterflow is vooraf ingesteld en kan niet worden veranderd zie de specificaties voor de waterflow van uw model 3 Na het inschakelen begint links de waterflow met 50 vermogen gedurende 5 seconden dan 75 vermogen gedurende 5 seconden en dan 100 vermogen gedurende 5 seconden gevolgd door 5 seconden pauze da...

Page 8: ...wing date of purchase will be considered You must supplytheentireunitwithaccessoriesintheeventofawarrantyclaim We will inform you on receipt whether the unit will be repaired or replaced We accept no responsibility for damage as a result of incorrect use of the unit Breakages of parts not due to defects ex factory are not covered by this warranty D Garantiebedingungen 2 Jahre Werksgarantie auf Mat...

Reviews: