SECTION
3
VACUUM HOSE
Connect the vacuum hose to the vacuum
inlet connection at the front of the waste
recovery tank. Connect the opposite end of
the vacuum hose to the cleaning tool.
JET SIZING
BLUELINE
recommends that the total floor
tool size does not exceed “.045”. Using
larger jet sizes on your
BLUELINE
HAZINATOR
®
unit may reduce cleaning
temperatures.
Example:
Four jet wand uses four 9501 jets.
(95 deg. Spray angle w/01 orifice)
.01 x 4 = .040
Upholstery tool jet size: 80015.
Stair tool jet size: 9502
STARTING THE UNIT
The high-pressure switch will automatically
shut down the unit if the water pressure in
the system exceeds 3000 PSI, for more than
5 seconds, with the water pump in the on
position.
1. Set the throttle cable control to the idle
position.
2. Pull the choke cable out.
3. Turn the ignition switch to the right
intermediate position. Hold the switch in
this position for approximately 3 seconds,
allowing the fuel pump to pump fuel.
4. Turn the ignition switch to the furthest
right position. This will engage the starter
and start the engine.
5. After starting the engine, push the choke
in.
6. After the engine is running at its idle
setting, select the desired speed setting using
the throttle control cable.
7. Turn the water pump switch to the
ON
position.
NOTE:
If the unit does not build water
pressure after 5 seconds, check for adequate
water supply. See “Loss of Water Pump
Pressure in the “
Troubleshooting
section of
this manual.
OPERATION
After you have completed the previous
steps, proceed with the cleaning operation.
Place the throttle control cable to the desired
cleaning mode for restoration or cleaning. A
float shut-off switch is located inside of the
waste tank. It will automatically shut down
the unit if the tank reaches its full capacity.
If this occurs, empty the waste tank before
continuing.
NOTE:
When only doing fluid
recovery, the water pump should be in the
OFF
position.
BLUELINE HAZINATOR
®
13