10
SAFETY INFORMATION
CAUTION
This pump is designed for home sump applications. The pump is equipped with a 3-prong
grounding-type power cord. The ball bearings on the motor shafts never need to be lubricated.
This pump has not been tested or approved for use in swimming pools or in salt-water marine
areas. It is also not engineered to be run continuously as a “fountain” or “waterfall” pump.
Because this pump has an oil-filled motor, it should NOT be used in water containing fish.
Pump only water with this pump. For safety, the pump motor has an automatic resetting
thermal protector that automatically will turn off the pump if it becomes too hot. Overuse of
this feature will damage the pump and will void the warranty. Once the thermal protector
detects that the pump has cooled to a safe temperature, it will allow the pump to operate
normally. If the pump is plugged in, it may restart unexpectedly.
•
This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free
service for a long time when properly installed, maintained, and used. However, inadequate
electrical power to the pump, dirt, or blockage by ice or debris may cause the pump to fail,
eventually bringing about additional water damage. To minimize the potential for water
damage due to pump failure, please carefully read the manual and follow the instructions
regarding common pump problems and remedies.
•
•
Installation
Verify the switch is operating without any obstruction from the pump, piping and basin.15.
Fill the basin/pit with water again. While the pump is draining the basin/pit, verify the
discharge pipe is carrying the water to a point at least 3 ft. away from the foundation.
the pipe must be positioned in a downward slope away from the foundation, so any
remaining water will drain away and not freeze.
•
Step 6:
Secure the basin cover and gasket to the basin to prevent debris from falling into the basin,
prevent personal injury, and to contain gases and/or odors.
•
Step 7:
Verify the switch is operating without any obstruction from the pump, piping and basin.
Fill the basin/pit with water again. While the pump is draining the basin/pit, verify the
discharge pipe is carrying the water to a point at least 3 ft. away from the foundation.
The pipe must be positioned in a downward slope away from the foundation, so any
remaining water will drain away and not freeze.