2
Recessed mounted option Fig 3
Cut a rectangular hole for the recessed Flood light at 121mm x 56mm using a multi tool with the
appropriate cutter for the material. Place the Light into the hole and mark and drill the four screw
holes using a 3mm drill.
Screw the light in place using the four screws provided.
Electrical connection:
Only attach the light cable to a waterproof connection or junction box, the cable must have a
watertight connection otherwise your
warranty will be void
.
Care should be taken when planning your electrical feeds/cables to the lights so as to ensure voltage
drop between the batteries or power supply is minimised, on 12V systems this is especially important
as the lower system voltage means a high current requirement which in turn means the potential for
more voltage drop in the cable runs & connections.
If the cable gauge & connections are not sufficient for the lighting load attached you may experience
incorrect operation of the lights & intermittent illumination as the supply dips below specification.
Please see the wire gauge guide attached to the instruction manual.
For help with calculations always consult with a qualified professional or contact Bluefin LED directly.