![Blueair BLMI-300A Service Manual Download Page 44](http://html.mh-extra.com/html/blueair/blmi-300a/blmi-300a_service-manual_2777163044.webp)
content
Ambient
Temp
(
º
F/
º
C)
Water temp(
º
F/
º
C)
50
º
F/10
º
C
70
º
F/21
º
C
90
º
F/32
º
C
High pressure in
freezing
(psig / kgf/
㎠
g)
after
5min
70/21
333.5
23.5
348.3
24.5
354.0
24.9
80/27
369.9
26.0
401.0
28.2
405.5
28.5
90/32
415.1
29.2
441.7
31.1
458.1
32.2
100/38
473.7
33.3
485.5
34.1
509.7
35.8
Stable
70/21
314.3
22.1
321.4
22.6
344.2
24.2
80/27
366.3
25.8
371.2
26.1
378.3
26.6
90/32
414.8
29.2
422.0
29.7
426.7
30.0
100/38
469.8
33.0
474.5
33.4
474.6
33.4
Low pressure in
freezing
(psig / kgf/
㎠
g)
after
5min
70/21
77.5
5.5
82.3
5.8
85.7
6.0
80/27
79.0
5.6
83.3
5.9
92.8
6.5
90/32
81.6
5.7
89.8
6.3
99.6
7.0
100/38
82.4
5.8
91.6
6.4
101.4
7.1
Stable
70/21
56.9
4.0
58.3
4.1
59.7
4.2
80/27
60.4
4.3
60.4
4.3
63.1
4.4
90/32
64.0
4.5
64.5
4.5
65.4
4.6
100/38
64.5
4.5
67.8
4.8
83.1
5.8
High pressure in
harvest
(psig / kgf/
㎠
g)
Stable
70/21
158.6
11.2
162.1
11.4
209.1
14.7
80/27
161.4
11.4
179.9
12.7
217.6
15.3
90/32
165.5
11.6
188.7
13.3
216.2
15.2
100/38
167.1
11.8
199.1
14.0
220.9
15.5
Low pressure in
harvest
(psig / kgf/
㎠
g)
Stable
70/21
127.5
9.0
140.8
9.9
164.3
11.6
80/27
123.0
8.7
145.1
10.2
167.4
11.8
90/32
123.0
8.7
149.3
10.5
168.3
11.8
100/38
124.5
8.8
151.2
10.6
170.0
12.0
Summary of Contents for BLMI-300A
Page 1: ...SERVICE MANUAL BLMI 300A BLMI 500A BLMI 650A BLMI 900A Ver200626 ...
Page 35: ...4 Circuit diagrams and technical data 4 1 Circuit diagrams 4 1 1 BLMI 300A 115V 60Hz ...
Page 36: ...4 1 2 BLMI 500A 115V 60Hz ...
Page 37: ...4 1 3 BLMI 650A 208 230V 60Hz ...
Page 38: ...4 1 4 BLMI 900A 208 230V 60Hz ...