2)
Parameter code meaning
Number Dislay
Features
Range
Settable value
Unit
1
P-1
Set evaporator temperature for
harvest control
5 ~ 30
41 ~ 86
1
℃
℉
2
P-2
Set harvest delay time
60 ~ 300
5
sec
3
P-3
Set drainage cycle interval
1 ~ 10
1,2,5,10
-
4
P-4
Sensor temperature correction
-2 ~ 2
-4 ~ 4
0.1
1
℃
℉
5
P-5
Set water pump delay time to prevent
ice from becoming slush.
10~60
1
sec
6
P-6
Set PCB program
25A~90A
Model name
-
7
P-7
Set water pump operation time
during harvest cycle
0 ~ 300
1
sec
8
P-8
Reset freezing cycle count
0~1
1
-
9
P-9
Set drainage time
10~20
10
sec
10
P-10
Set water supply time during harvest
0~300
10
sec
11
P-11
Set minimum freezing time
0~30
1
min
12
P-12
Set tempearture display unit
℃
,
℉
-
-
13
P-13
Set hertz
50,60
-
hz
-
P-1 / Set evaporator temperature for harvest control: Once evaporator sensor
reaches the set temperature, harvest cycle will be done. [Default Setting : 7℃
(44.6
℉
)]
-
P-2 / Set harvest delay time after evaporator sensor reaches a set temperature
[Default: 7
℃
((44.6
℉
)] for harvest. Default harvest delay time depends on model.
-
P-3 / Set drainage cycle interval to drain remaining water at the bottom of water
tank. [Default: Every 10 freezing cycles]
-
P-4 / Set the correct temperature range if there is a temperature discrepancy
between sensor and actual thermometer. [Default : 0 ]
-
P-5 / Set water pump delay time to prevent ice from turning to slush. Set the
pump motor to stop when the evaporator sensor reads the set temperature. This
will prevent the ice from turning to slush. [Default : 15 seconds]
Summary of Contents for BLMI-300A
Page 1: ...SERVICE MANUAL BLMI 300A BLMI 500A BLMI 650A BLMI 900A Ver200626 ...
Page 35: ...4 Circuit diagrams and technical data 4 1 Circuit diagrams 4 1 1 BLMI 300A 115V 60Hz ...
Page 36: ...4 1 2 BLMI 500A 115V 60Hz ...
Page 37: ...4 1 3 BLMI 650A 208 230V 60Hz ...
Page 38: ...4 1 4 BLMI 900A 208 230V 60Hz ...