background image

®

CHEM-PRO  C2F/C3F

Congratulations on purchasing Chem-Pro® variable speed Diaphragm Metering Pump. A diaphragm pump is a 
type of positive displacement pump used for pumping a variety of fluids.

Your Chem-Pro® pump is pre-configured for diaphragm, pump head and fittings that shipped with your metering 
pump.

Please Note:

   Your new pump has been pressure tested at the factory with clean water before shipping. You may 

notice trace amounts of clean water in pump head. This is part of our stringent quality assurance program at Blue-
White Industries.

Page 3

1.1      Available Models

n

Raise metering pump 4-1/2 inches (11.43 cm) off ground or a surface.

n

Made out of tough Stainless Steel.

n

Provides a stable mounting surface.

Stainless Steel extended brackets allow pump to be securely mounted to most any surface; 
floor, shelf, or skid. Brackets lift pump up 4-1/2 inches (11.43 cm), for easy pump access in 
hard to reach areas.

Model #

72000-380

Description

Extended Mounting Bracket, 1 Pair, SS, 4 SS Screws

Optional Extended Brackets

1.0 

Introduction

 230V AC

C2F253XVA

C2F253XVB
C2F253XVC
C2F253XVD

C2F251XVA

C2F251XVB
C2F251XVC
C2F251XVD

C2F252XVA

C2F252XVB
C2F252XVC
C2F252XVD

115V AC

C2F243XVA

C2F243XVB
C2F243XVC
C2F243XVD

C2F241XVA

C2F241XVB
C2F241XVC
C2F241XVD

C2F242XVA

C2F242XVB
C2F242XVC
C2F242XVD

 Fittings

1/2” Male NPT / PVDF

1/2” Female NPT / PVDF

1/2” Hose Barb / PVDF

3/8” Tube compression/ PVDF

1/2” Male NPT / PVDF

1/2” Female NPT / PVDF

1/2” Hose Barb / PVDF

3/8” Tube compression/ PVDF

1/2” Male NPT / PVDF

1/2” Female NPT / PVDF

1/2” Hose Barb / PVDF

3/8” Tube compression/ PVDF

 220V AC

C2F263XVA

C2F263XVB
C2F263XVC
C2F263XVD

C2F261XVA

C2F261XVB
C2F261XVC
C2F261XVD

C2F262XVA

C2F262XVB
C2F262XVC
C2F262XVD

Connection Type

Feed Rate at 0 PSIg

C2F   Model Numbers

 PSIg (bar)

175 (12)
175 (12)
175 (12)
175 (12)
175 (12)
175 (12)
175 (12)
175 (12)
175 (12)
175 (12)
175 (12)
175 (12)

Max

Pressure

C2F Diaphragm Metering Pump

No Metal in fluid path

Max. 166 Strokes Per Minute

 230V AC

C3F251XVA

C3F251XVB
C3F251XVC

C3F252XVA

C3F252XVB
C3F252XVC

115V AC

C3F241XVA

C3F241XVB
C3F241XVC

C3F242XVA

C3F242XVB
C3F242XVC

 Fittings

1/2” Male NPT / PVDF

1/2” Female NPT / PVDF

1/2” Hose Barb / PVDF

1/2” Male NPT / PVDF

1/2” Female NPT / PVDF

1/2” Hose Barb / PVDF

 220V AC

C3F261XVA

C3F261XVB
C3F261XVC

C3F262XVA

C3F262XVB
C3F262XVC

Connection Type

Feed Rate at 0 PSIg

C3F   Model Numbers

 PSIg / bar

150 / 10.3
150 / 10.3
150 / 10.3

100 / 6.8
100 / 6.8
100 / 6.8

Max

Pressure

C3F Diaphragm Metering Pump

No Metal in fluid path

Max. 130 Strokes Per Minute

!

Chem-Pro® Pumps motor speed is linear over the entire 1% to 100% adjustment range. 

!

Output versus pressure is nearly linear in all models.

!

Feed rates taken in laboratory environment with clean water after 20 minute diaphragm break-in period with a 3 foot (1 meter) suction lift.

LPH

.254 - 25.4
.254 - 25.4
.254 - 25.4
.254 - 25.4

.38 - 38
.38 - 38
.38 - 38
.38 - 38

.625 - 62.5
.625 - 62.5
.625 - 62.5
.625 - 62.5

GPH

.067 - 6.7
.067 - 6.7
.067 - 6.7
.067 - 6.7

.10 - 10
.10 - 10
.10 - 10
.10 - 10

.165 - 16.5
.165 - 16.5
.165 - 16.5
.165 - 16.5

ML/Min

4.23 - 423
4.23 - 423
4.23 - 423
4.23 - 423
6.31 - 631
6.31 - 631
6.31 - 631
6.31 - 631

10.41 - 1041
10.41 - 1041
10.41 - 1041
10.41 - 1041

LPH

.99 - 99
.99 - 99
.99 - 99

1.54 - 154
1.54 - 154
1.54 - 154

GPH

.262 - 26.2
.262 - 26.2
.262 - 26.2
.406 - 40.6
.406 - 40.6
.406 - 40.6

ML/Min

16.50 - 1650
16.50 - 1650
16.50 - 1650
25.60 - 2560
25.60 - 2560
25.60 - 2560

Summary of Contents for ProSeries CHEM-PRO C2F Series

Page 1: ...Business Drive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white com techsupport blue white com URL www Blue White com SERIES C2F C3F Operating Manual ProSerie...

Page 2: ...O Schematics 9 6 0 How to Operate Chem Pro Control Pad 10 7 0 Set Remote Start Stop 11 7 1 Set FVS Flow Verification Sensor 12 8 0 Manual Operation 14 9 0 DFD Diaphragm Failure Detection 15 10 0 Alar...

Page 3: ...rb PVDF 3 8 Tube compression PVDF 220V AC C2F263XVA C2F263XVB C2F263XVC C2F263XVD C2F261XVA C2F261XVB C2F261XVC C2F261XVD C2F262XVA C2F262XVB C2F262XVC C2F262XVD Connection Type Feed Rate at 0 PSIg C2...

Page 4: ...to 158 F 40 C to 70 C Operating Voltage 115VAC 60Hz 1ph 1 5 Amp Maximum 230VAC 60Hz 1ph 0 7 Amp Maximum 220VAC 50Hz 1ph 1 0 Amp Maximum 240VAC 50Hz 1ph 1 0 Amp Maximum Power Cord Options 115V60Hz NEMA...

Page 5: ...tandard 778 as a motor operated water pump CSA Standard C22 2 as process control equipment This pump complies to the Machinery Directive 98 37 EC BS EN 60204 1 Low Voltage Directive 73 23 EC BS EN 610...

Page 6: ...rt before installing metering pump on specialized systems Metering pump should be serviced by qualified persons only Always wear protective clothing face shield safety glasses and gloves when working...

Page 7: ...Models Injection Fitting and Strainer Suction Tubing and Strainer Suction Tubing PVC 3 8 95 cm OD X 1 4 64 cm ID PVDF PVDF O Ring TFE P optional EP O Ring TFE P optional EP Spring Hastelloy C 276 Bal...

Page 8: ...n auto restart feature which will restore pump to operating state it was in when power was lost Note When in doubt regarding your electrical installation contact a licensed electrician Electrical conn...

Page 9: ...232 T12 POWER F1 2 Motor Active 5 T4 FVS 3 4 5 SIG BLUE WHITE FVS SENSOR GND SIGNAL PWR RED BLACK BARE T3 REMOTE IN 3 1 2 DRY RMT COM T3 T3 1 2 POSITIVE NEGATIVE T3 T3 2 3 POSITIVE NEGATIVE T3 REMOTE...

Page 10: ...hile in programming mode Time out Chem Pro pumps have a time out setting of approximately 20 seconds while in configuration menu If built in timer exceeds 20 seconds without a button being pressed the...

Page 11: ...nd holding START STOP button for a few seconds until you return to Run screen Running pump with Remote Start Stop enabled REMOTE icon will always be visible on lower left side of screen Pump will disp...

Page 12: ...a delay time in seconds Delay time is amount of time pump will wait to receive a pulse from sensor until an alarm is triggered A delay time of 00 deactivates FVS feature FVS 0 00 0 Step 5 After you ve...

Page 13: ...dapter Thread sensor onto pump tube until tubing insert is snug against pump tube fitting do not over tighten 7 1 Set FVS flow verification system Continued Sensor Model Number Actual Working Range wi...

Page 14: ...Runtime Screen Shot 1 Displays motor speed percentage Pump Running in Manual Operation 35 0 SPEED 35 0 REMOTE Runtime Screen Shot 2 Displays motor speed percentage Pump Running in Manual Operation wi...

Page 15: ...le of detecting presence of a large number of chemicals including Sodium Hypochlorite Chlorine Hydrochloric muriatic Acid Sodium Hydroxide and many others System will not be triggered by water rain co...

Page 16: ...est is most accurate for measuring injector s output in an individual installation C3V Diaphragm Metering Pump Made in the USA MODE PRIME Program Minimum Maximum Blue White Ind IP66 NEMA 4X Suction Tu...

Page 17: ...able materials Manufacturer does not assume responsibility for damage to pump that has been caused by chemical attack Brush Kit Life Cycle over 3 000 hours of continuous use A spare brush kit is locat...

Page 18: ...nnecting top and bottom may become unplugged if pulled too far apart Step 5 Unscrew and remove brush caps by turning counter clockwise Step 6 Remove used brushes and discard properly Step 7 Insert new...

Page 19: ...Model C2x2x5 166 RPM Small Diaphragm 040 Offset 0 25 1 7 50 3 4 75 5 2 100 6 8 125 8 6 150 10 3 PSIg Bar Feed Rate LPH 18 9 3 8 7 6 11 4 15 1 175 12 0 18 9 3 8 7 6 11 4 15 1 Model C3x2x2 130 RPM 100 S...

Page 20: ...P HEAD SM SPACER 13 90003 561 BUMPER FEET 4 90002 326 UV LCD CVR PLYCRB 1 14 6 7 8 76001 361 SUCTION TUBE 8 FOOT Not included with all models 13 14 3 2 1 22 21 21 22 71000 575 71000 447 71000 325 9000...

Page 21: ...LVE 5 T BARB VIT 70001 348 VALVE 5 T BARB EP 8 20000 194 KIT 4 EA VALVE VIT 1 20000 195 KIT 4 EA VALVE EP 9 72000 295 DIAPHRAGM KIT C3 13 90003 561 BUMPER FEET 4 90002 326 UV LCD CVR PLYCRB 1 71010 02...

Page 22: ...Foot Valve CHEM PRO TM tm CHEM PRO C3V Diaphragm Metering Pump Made in the USA MODE PRIME Program Minimum Maximum Blue White Ind IP66 NEMA 4X Suction Tubing Injection Check Valve Chemical Tank Discha...

Page 23: ...t the highest quality standards in the industry Each product instruction manual includes a description of the associated product warranty and provides the user with important safety information Purcha...

Page 24: ...an health due to the presence of hazardous substances The WEEE marking applies only to countries within the European Union EU and Norway Appliances are labeled in accordance with European Directive 20...