![Blue-White CHEM-FEED CD1 Series Operating Manual Download Page 8](http://html1.mh-extra.com/html/blue-white/chem-feed-cd1-series/chem-feed-cd1-series_operating-manual_2777005008.webp)
Page 8
5.2 Wall Mounting
1. Using the provided #10 self-tapping screws, mount the bracket to a secure wall that is located where it can be
easily serviced.
#10 Self-Tap
(2 X)
4.50 in.
[11.43 cm]
Wall Mount Bracket (Side View)
Mounted Pump (Front View)
2. Lower the pump so that the tab on the wall mount is inserted into the slot located on the back of the pump. The
pump will now be secured to the wall mount bracket.
Wall Mount Tab
Wall Mount (Side View)
Wall mount slot
Mounted Pump
Page 9
CHEM-FEED CD1
CHEM-FEED CD1
5.3
4-20mA Input
Proper eye and skin protection must be worn when installing and servicing the pump.
CAUTION
!
Directions
1
Confirm that pump is in the OFF position
2
Press 4-20mA Input button
1
2
5.31 Selecting 4-20mA input mode
Directions
1
Confirm that pump is in the OFF position.
2
Press and hold 4-20mA Input button.
3
MIN mA light will illuminate. Use arrow
keys to toggle min mA value for the pump
to operate at
4
Press 4-20mA Input button for MIN %
Speed light to illuminate
5
Use arrow keys to toggle MIN % Speed
value for the pump to operate.
6
Press 4-20mA Input button for MAX mA
light to illuminate.
7
Use arrow keys to toggle MAX mA value
for the pump to operate.
8
Press 4-20mA Input button for MAX %
Speed light to illuminate.
9
Use arrow keys to toggle MAX % Speed
value for the pump to operate.
10
Press and hold 4-20mA Input button to exit
programming mode.
1
3
2
5.32 Programming 4-20mA input mode