Blue-White industries A3V series Operating Manual Download Page 38

LIMITED WARRANTY

Your new Flex-Pro pump is a quality product and is warranted for 24 months from date of purchase (proof of purchase is required).  The 
pump will be repaired or replaced at our discretion.  Pump Head and roller assembly is warrantied against damage from chemical 
attack when proper TFD (Tube Failure Detection) system instructions and maintenance procedures are followed.

 

WHAT IS NOT COVERED

Pump Tube Assemblies and rubber components – They are perishable and require periodic replacement.

Pump removal, or re-installation, and any related labor charge.

Freight to the factory, or ProSeries service center.

Pumps that have been tampered with, or in pieces.

Damage to the pump that results from misuse, carelessness such as chemical spills on the enclosure, abuse, lack of 
maintenance, or alteration which is out of our control.

Pumps damaged by faulty wiring, power surges or acts of nature.

Blue-White Industries does not assume responsibility for any loss, damage, or expense directly or indirectly related to or arising out of 
the use of its products.  Failure must have occurred due to defect in material or workmanship and not as a result of operation of the 
product other than in normal operation as defined in the pump manual.
Warranty status is determined by the pump's serial label and the sales invoice or receipt.  The serial label must be on the pump and 
legible.  The warranty status of the pump will be verified by Blue-White or a factory authorized service center.

OTHER IMPORTANT WARRANTY INFORMATION

Please be advised; injection and metering devices are not intended as a means of treating water to render it suitable for human 
consumption.  When used as hypochlorinators, they are meant to destroy bacteria and algae contamination, before its removal by 
filtration.  Acid and soda injectors are used for PH control (balance).  Blue-White injectors are factory tested with water only for pressure 
and performance.  Installers and operators of these devices must be well informed and aware of the precautions to be taken when 
injecting various chemicals -especially those considered hazardous or dangerous, eye protection must be worn when working around 
this product or any other metering type of pump.
Should it become necessary to return the pump for repair or service, you must attach information regarding the chemical used as some 
residue may be present within the unit which could be a hazard to service personnel.
Blue-White Industries will not be liable for any damage that may result by the use of chemicals with their injectors and its components.  
Thank you.

PROCEDURE FOR IN WARRANTY REPAIR

Contact the factory to obtain a RMA (Return Material Authorization) number. Carefully pack the pump to be repaired. It is recommended 
to include foot strainer and injection/check valve fitting since these devices may be clogged and part of the problem.  Please enclose a 
brief description of the problem as well as the original invoice or sales receipt, or copy showing the date of purchase.  Prepay all 
shipping costs.  COD shipments will not be accepted.  Warranty service must be performed by the factory or an authorized ProSeries 
service center.  Damage caused by improper packaging is the responsibility of the sender.  When In-Warranty repair or replacement is 
completed, the factory pays for return shipping to the dealer or customer.

Users of electrical and electronic equipment (EEE) with the WEEE marking per Annex IV of the WEEE Directive must not 
dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to them for the return, 
recycle, recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the 
presence of hazardous substances. The WEEE marking applies only to countries within the European Union (EU) and Norway. 
Appliances are labeled in accordance with European Directive 2002/96/EC. 
Contact your local waste recovery agency for a 

Designated Collection Facility

 in your area.

P.N. 80000-463

Rev. 06182012

5300 Business Drive, Huntington Beach, CA 92649    USA

Phone:

 714-893-8529     

FAX:

 714-894-9492

E mail:

 [email protected]  

or

  [email protected]    

URL:

 www.blue-white.com

ProSeries

by Blue-White Ind.

TMR

Summary of Contents for A3V series

Page 1: ...com URL www blue white com SERIES A3V and A4V Operating Manual ProSeries by Blue White Ind TM FLEX PRO Peristaltic Metering Pump system TFD Tube Failure Detection Exclusive 2 TWO YEAR WARRANTY ProSer...

Page 2: ...re Input Remote start stop 25 4 5 Set FVS Flow Verification System 26 4 6 TFD Tube Failure Detection 27 4 6 1 TFD Adjustment 27 4 7 Remote Local Control 28 4 8 Pump Tube Timer 28 5 0 Output Setup Alar...

Page 3: ...5 NH A4V25 NJ A4V25 NL A4V25 NP A4V25 NK A4V25 NHH 115V AC A4V24 NH A4V24 NJ A4V24 NL A4V24 NP A4V24 NK A4V24 NHH 220V AC A4V26 NH A4V26 NJ A4V26 NL A4V26 NP A4V26 NK A4V26 NHH ML Min 7 1800 1 1 2800...

Page 4: ...tactile switch keypad Security Programmable 4 digit password 0 1 increments 10 motor speed 0 01 increments 1 motor speed and 10 0 001 increments 1 motor speed Wetted components Non Wetted components P...

Page 5: ...nd three 115V 1A contact closures assignable to monitor up to 17 different pump functions including TFD FVS remote local control setting motor on fault current operating mode and others Two CNC precis...

Page 6: ...tems Metering pump should be serviced by qualified persons only n Raise metering pump 4 1 2 inches 11 43 cm off ground or a surface n Made out of tough Stainless Steel n Provides a stable mounting sur...

Page 7: ...calcium buildup when injecting chemicals that calcify such as sodium hypochlorite Duckbill may add additional back pressure to pump up to 7 psi 3 8 OD x 1 4 ID Tubing and Tri Clamp connection Models...

Page 8: ...and power cables together Power Interruption This pump has an auto restart feature which will restore pump to operating state it was in when power was lost Note When in doubt regarding your electrical...

Page 9: ...MAX AT 30 VOLT DC Form C 1 AMP MAX AT 125 VOLT AC 0 8 AMP MAX AT 30 VOLT DC Form C 1 AMP MAX AT 125 VOLT AC 0 8 AMP MAX AT 30 VOLT DC 5A SLOW BLOW 20 X 5MM 1 2 3 T1 PULSE GND 4 20 1 2 3 T1 PULSE GND...

Page 10: ...arrow at same time while in the normal operating mode Screen will display current Pump Tube Time in run time hours While displayed press ENTER button twice to reset Pump Tube Timer to zero Press and r...

Page 11: ...o see a list of all available options Scroll bar example While making a selection where only one choice is allowed you will see a radio button Radio button example In a screen where you are making cha...

Page 12: ...ay Language Esc Reset to Defaults Set Password Display Rate Reset to Factory Defaults Reset to Factory Defaults Reset to Factory Defaults Are you sure Yes No Liter Hr Gal Hr US Gal day US Done Display...

Page 13: ...r selected Display Rate Press MENU button to enter menu structure for setting up pump Select Configuration and Press ENTER button Select Display Rate and Press ENTER button Select your desired Display...

Page 14: ...s and allow local touch pad control only Set FVS Max Flowrate Input Max Flowrate Flowrate ML min Press ENTER to set 0000 0 1 Contact Input Close Stop Pump Open Stop Pump Input Time Delay OFF 000 Range...

Page 15: ...Press ENTER button Press UP or DOWN arrow to scroll through 0 9 on selected digit Press RIGHT arrow to scroll over to next digit to right If you pass your desired digit you can easily scroll back by c...

Page 16: ...back out of menu structure To do this you must select Esc at bottom of every screen menu until you see Run Mode screen displayed Tip This feature can be combined with Contact Input feature to allow fo...

Page 17: ...ct Esc at bottom of every screen menu until you see Run Mode screen displayed 4 20 mA Input Motor Min Signal Input Motor Speed at Minimum mA Signal 00 0 0 4 20 mA Input Min mA Signal Input Min mA sign...

Page 18: ...cture To do this you must select Esc at bottom of every screen menu until you see Run Mode screen displayed 0 10 VDC Input Motor Min Signal Input Motor Speed at Minimum Volt DC Signal 00 0 0 0 10 VDC...

Page 19: ...uency Input setup you must navigate back out of menu structure To do this you must select Esc at bottom of every screen menu until you see Run Mode screen displayed Frequency Input Motor Min Signal In...

Page 20: ...hold Select Run Mode button until Run Mode screen is displayed If you used Menu button to navigate to Pulse Batch setup you must navigate back out of menu structure To do this you must select Esc at b...

Page 21: ...etup then just press and hold Select Run Mode button until Run Mode screen is displayed If you used Menu button to navigate to Cycle Adjustment setup you must navigate back out of menu structure To do...

Page 22: ...ow to scroll through 0 9 on selected digit Press RIGHT arrow to scroll over to next digit to right If you pass your desired digit you can easily scroll back by continuously pressing RIGHT button Press...

Page 23: ...r desired digit you can easily scroll back by continuously pressing RIGHT button Press ENTER to save changes Continue this process until all four screens have been configured If you used short cut to...

Page 24: ...easily scroll back by continuously pressing RIGHT button Press ENTER to save the changes Continue this process until all four screens have been configured If you used short cut to enter Proportional...

Page 25: ...croll down to Done selection Then press ENTER To navigate back out of menus select Esc and press the ENTER button at bottom of every screen menu until you see Run Mode screen displayed IMPORTANT If Co...

Page 26: ...arm occurs pump will stop send an external signal if setup and screen will flash FVS with an alarm icon To clear FVS alarm you must press START button or re cycle power unplug power to pump then plug...

Page 27: ...emical enters pump head This patented system is capable of detecting presence of a large number of chemicals including Sodium Hypochlorite Chlorine Hydrochloric muriatic Acid Sodium Hydroxide and many...

Page 28: ...Contact Input Set FVS Esc Hidden Set Rev Alarm Set TFD Remote Local Remote Local Remote Only Local Only Disable Done select one Remote Only Input Mode 4 20 mA 0 10 VDC Frequency select one Hidden Don...

Page 29: ...00 0 04 00 100 00 20 00 Pump Run Stop Frequency Mode Cycle Timer Mode Dispensing Mode Manual Dosing Prop Dosing 0 10 VDC Mode Pulse Mode Disable FVS TFD Pump Run Stop 4 20mA Mode Manual Mode Frequency...

Page 30: ...utput 4 mA 100 Pump Output 20 mA Signal Output Frequency Output Disable Done 4 20 mA Output Default 4 20 mA output settings shown Signal Output Disable Done 4 20 mA Output Default Frequency Hz output...

Page 31: ...cting fluids that calcify such as sodium hypochlorite These lime deposits and other build ups can clog the fitting increasing the back pressure at the pump reducing tube life and interfering with chec...

Page 32: ...s around Stop pump by pressing STOP button Thoroughly clean Pump Head and Rotor Rotor can be removed by pulling straight out After cleaning process push Rotor back on shaft See drawing above for prope...

Page 33: ...ough room to slide discharge fitting into pump head tongue and groove Once discharge fitting is secured in pump head stop pump by pressing STOP button Replace pump head cover Pump will ask you if you...

Page 34: ...ded mounting bracket kit pair Rubber feet 72000 380 90003 561 1 4 Not Shown Stainless Steel mounting bracket kit pair 72000 379 1 Not Shown Not Shown 4 Tube Assembly 1 2 Male NPT connect Norprene ND 0...

Page 35: ...50 ID Tube Assembly 1 2 Male NPT Norprene NP 75 ID A4 MGH R A4 BGH T A4 BGK T A4 MGH T A4 MGK T A4 MNL R A4 BNL T A4 BNP T A4 MNL T A4 MNP T 1 1 1 1 1 1 1 1 1 1 4 4 4 4 Tube Assy 1 2 hose barb Dual Ty...

Page 36: ...Flex Pro Page 36 7 2 Output Versus Fluid Viscosity A3 A3 A3 A3...

Page 37: ...Page 37 Flex Pro A4 A4 A4 A4...

Page 38: ...precautions to be taken when injecting various chemicals especially those considered hazardous or dangerous eye protection must be worn when working around this product or any other metering type of...

Reviews: