Page | 11
V14612INSLM
To replace the Cassette in the water valve:
1.
Turn pump off
2.
Loosen the bolt on band clamp and remove the band clamp and clear lid.
3.
Remove the turbine and old cassette by sliding them off of the center shaft.
4.
Install the new cassette by sliding it onto the center shaft. Spin the gears and make
sure the cassette drops all the way down and the lower gears engage with the gear
train on the housing perimeter.
5.
Place the turbine on the center shaft gear side down. Make sure the gear on the
turbine engages the upper gear on the cassette. Spin the turbine several times and
observe the white bottom plate is slowly turning. If it does not the cassette is not in
the full “down” position and the lower gear is above the gear train on the housing
perimeter.
6.
Check positioning of large 0-ring on the clear lid.
7.
Align the center shaft on the guide pin hole in the center of the clear lid and gently
push the lid down. The lid should seat firmly seat on the top of the valve housing with
no wobble.
8.
Replace the band clamp and tighten the bolt firmly. Do not over tighten.
Thank you for purchasing a Blue Square Q360 In-Floor Cleaning System! With over 20
years of pool building and in-floor knowledge, this system was designed with you and the
homeowner in mind. This cost effective and efficient system is truly innovative with a very
simple approach to installation and repair; making it easy for the homeowner to keep
their pool clean and, should there be a problem to arise, easy to fix. We are here to
answer questions, resolve issues and provide exceptional customer service.
Blue Square Manufacturing, LLC
525 East Baseline Road
Suite 107
Gilbert, AZ 85233
Office 480.612.6880 Toll Free 800.277.4150