Blue Square Labs Q360 Installation And Maintenance Manual Download Page 10

Page | 10  

 

                                                                                                                              

V14612INSLM 

 
CLEANING THE FILTRATION SYSTEM 

For optimum cleaning efficiency, routinely clean the 
pump basket, skimmer and filter screens.  Backwash or 
clean the pool filter whenever pressure increases 5-10 psi 
above normal clean-filter operating pressure or if you 
notice dirty spots between the jets. 

 
CHANGING CLEANING HEADS 

The cleaning jets must be in the full down position before 
removal. 

1.

 

Attach the Jet Removal Tool to the pool pole 

2.

 

Snap tool into the jet 

3.

 

Turn counter-clockwise to release head from 
collar 

4.

 

Pull and lift the jet out of the collar 

To reinstall, simply insert head into collar and turn 
clockwise to lock into position. 
 

TROUBLESHOOTING 

 
If the Blue Square Q360 cleaning system displays the following actions, adjustments may 
be necessary to restore performance.  Refer to exploded parts diagram for part 
references. 
 

Action:  Dirty Spots appear

 

Solution:  Clean the pool filter, pump basket and skimmer baskets.   
Make sure all auxiliary valves (surface returns, waterfall, spa overflow, etc.) are closed. 
If you have a variable speed pump, check to make sure the pump is running at a 
sufficient RPM as recommended by your pool builder. 
 

Action:  Dirt is trapped between heads  

Solution:  Verify that the water flows from the jet nozzle on each side of dirty spot are not 
apposing one another.  To change the cleaning jet flow direction, press the jet down 5-6 
times while it is in the up position and the water is flowing out of the nozzle.   
 

Actions:  Cleaning jet advances, but is not cleaning, (dirt remains near the jet.) 

Solution: Remove the cleaning jet with the jet removal tool.  Check for debris lodged in 
the nozzle.  Make sure the jet freely travels up and down and ratchets slightly each time.  
If the jet does not, hold the jet in the up position and rinse with water to dislodge internal 
debris.  Run the pump, while the jet is removed, a full cycle until you see water flow out of 
the opening on the problem bank.  Let the system run without the jet until you are certain 
that all of the debris is blown out of the pipe. Re-insert the cleaning jet with the jet 
removal tool. 
 

Action:  Cleaning jet will not go down 

Solution: Try to gently touch the jet with the pool pole to see if it will retract, if the jet 
retract let the system run and see the problem is solved.  If the problem recurs, remove 
the jet with the jet removal tool.  Inspect the cleaning head and collar for or debris.  Run 
the pump, while the jet is removed, a full cycle through the problem bank, to blow out 
any debris. Re-insert the cleaning jet.  On variable speed pump applications, you may 
need to increase RPM’s to ensure jet fully ratchets to next position.  

Summary of Contents for Q360

Page 1: ...Page 1 V14612INSLM V Va al lv ve e I In ns st ta al ll la at ti io on n a an nd d M Ma ai in nt te en na an nc ce e G Gu ui id de e ...

Page 2: ...arranty fax or email a System Design Form provided by Blue Square along with a scaled pool plan for a FREE certified In Floor Design New pool construction only Email plans bluesquaremfg com Fax 888 282 6955 If the pool plan design or dimensions change during excavation a revised plan must be submitted to Blue Square in order to maintain warranties Install the valve above ground at finished pool wa...

Page 3: ...en gear design allows for effective pass through of debris greatly minimizing annoying cleaning system disruptions and lowering maintenance costs even further over other in floor systems The Innovative pressure safe valve design protects your system by ensuring that one port is always open Large 2 inlet and 6 2 ports maximize flow rate Reinforced space age molded construction weathers the elements...

Page 4: ...sts position the valve as close as possible to the swimming pool or water feature The valve should be at least five feet away from the water s edge Check the bonding codes in your area The low profile design the quiet and smooth operation of the Q360 Water Valve allows for the valve to be inconspicuously hidden by an irrigation box or landscaping Although servicing the valve is very rare the valve...

Page 5: ... or a different elevation body of water to prevent drain back or equalization See Fig A 1 3 Fig A 1 3 Follow the design plan to position and stake the cleaning head locations Each head has a designated nozzle that has a precise cleaning radius Perimeter heads have a one foot overlap Mark the cleaning radius around each stake ...

Page 6: ...riser with no reaming required These stub ups should be perpendicular to the slope of the pool floor Plumbing the Valve see Plumbing the System Diagram Remove the Cassette Gears during pressure testing to allow for equal distribution of pressure down all 6 ports or zones Store the Cassette with the jets for reinstallation at start up Position the O ring on the valve housing in the O ring groove Al...

Page 7: ...ll outlet ports on the valve are not needed use the Y Pipe as noted in the plan to aid in efficiency and reduce plumbing costs Note Surface returns can be applied to the unused port Never tie a raised spa bank with any plumbing from a lower body of water and drain down Consult the design plan for proper connections Auxiliary Equipment Heaters To compensate for heater system pressure drops plumb he...

Page 8: ... stub up ensuring collars sit at a height to accommodate approximately of final finish material Clean off all burs and debris 3 Insert test plug in each stub up 4 Attach a blower assembly unit blower check valve air water supply and connectors call Blue Square for assembly instructions to the blower plate or directly to the valve 5 Turn on blower and water supply to fill the lines 6 Starting at th...

Page 9: ...the top of the valve housing with no wobble If it does not sit firmly remove the turbine and press the cassette down into the gear train 8 Replace the band clamp and tighten the bolt firmly Do not over tighten 9 Turn on the system and allow it to cycle until all of the protective caps are blown free from the collar and to allow any additional construction debris to be blown out of the pipes 10 Aft...

Page 10: ...the water flows from the jet nozzle on each side of dirty spot are not apposing one another To change the cleaning jet flow direction press the jet down 5 6 times while it is in the up position and the water is flowing out of the nozzle Actions Cleaning jet advances but is not cleaning dirt remains near the jet Solution Remove the cleaning jet with the jet removal tool Check for debris lodged in t...

Page 11: ...meter 6 Check positioning of large 0 ring on the clear lid 7 Align the center shaft on the guide pin hole in the center of the clear lid and gently push the lid down The lid should seat firmly seat on the top of the valve housing with no wobble 8 Replace the band clamp and tighten the bolt firmly Do not over tighten Thank you for purchasing a Blue Square Q360 In Floor Cleaning System With over 20 ...