Installation
10
The regulator connections are
3
/
4
" BSP female.
The connection to the appliance is
3
/
4
" BSP male.
(Refer to the “Specifications” section for the gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
4.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the appliance is level and at the correct height.
5.
Connect the gas supply to the appliance. A suitable joining compound which resists the breakdown
action of LPG must be used on every gas line connection, unless compression fittings are used.
6.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
7.
Check that the gas operating pressure is as shown in “Specifications” section.
NOTE: The operating pressure to be measured at the manifold test point and with 2 burners
operating at the “High Flame” setting.
8.
Turn off the mains gas supply and bleed the
gas out of the appliance gas lines.
9.
Turn on the gas supply and the appliance.
10. Verify that the operating pressure remains
correct.
Commissioning
1.
Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
‘Operation’ section of this manual.
•
Lighting the Griddle.
•
Lighting the Open Burners (F - Flame Failure Option).
•
Lighting the Open Burners (PF - Pilot and Flame Failure Option).
•
Check the Low Fire burner operation.
•
Light the Oven Pilot and Main Burners.
•
Check the Oven Main Burner Thermostat operation.
•
Turning the Oven to ‘Stand-By’ Mode.
•
Oven ‘Shut Down’.
b. Ensure that the operator has been instructed in the areas of correct lighting, operation, and
shutdown procedure for the appliance.
2.
This manual must be kept by the owner for future reference, and a record of the
Date of
Purchase,
Date of Installation
and
Serial Number of the Appliance
recorded and kept with
this manual.
(These details can be found on the Rating Plate attached to the bottom right
hand corner of the bottom sill. Refer to the ‘Gas Connection’ section)
.
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
M a n i f o l d
Test Point
Fig 2