Troubleshooting

Problem

Possible Cause

Prevention/Cure

Burner will not light using igniter

Electrode and burners are wet.

Wipe dry with cloth.

Electrode cracked or broken - sparks at crack.

Replace electrode.

Wire loose or disconnected.

Reconnect wire or replace electrode/wire assembly

Wire is shorting (sparking) between igniter and electrode.

Replace igniter wire/electrode assembly

Bad igniter.

Replace igniter

Burner will not light with match

No gas flow.

Check if LP gas tank is empty. If LP gas tank is not empty, refer 
to “Sudden drop in gas flow (reduced flame height). If empty, 
replace or refill.

Coupling nut and regulator not fully connected.

Turning the coupling nut about one-half to three quarters 
additional turn until solid stop. Tighten by hand only-do not use 
tools.

Obstruction of gas flow.

Clear burner tubes. Check for bent or kinked hose.

Disengagement of burner to valve.

Reengage burner and valve.

Spider webs or insect nest in venturi.

Clean venturi.

Burner ports clogged or blocked.

Clean burner ports.

Sudden drop in gas flow or reduced flame height

Out of gas.

Check for gas in the LP gas tank

Excess flow safety device may have been activated.

Turn control knob to “OFF”, wait 30 seconds and light outdoor 
fire bowl. If flames are still too low reset the excessive flow 
safety device by turning off knobs and LP gas tank valve. 
Disconnect regulator. Turn burner control knobs to “HIGH”. Wait 
1 minute. Turn burner control knob off. Reconnect regulator and 
leak check connections. Turn LP gas tank valve on slowly, wait 
30 seconds and then light outdoor fire bowl.

Irregular flame pattern

Burner ports are clogged or blocked.

Clean burner ports.

Flame blow out

High or gusting winds

Increase flame height to “HIGH” setting

Low on LP Gas

Replace or refill LP gas tank

Excess flow valve tripped

Refer to “Sudden drop in gas flow”

Flame seems to lose heat when burning in cold weather 
- temperature below 50ºF

Ice has built up on the outside of the LP gas tank because the 
vaporization process is too slow.

Turn “OFF” the control knob and the LP gas tank. Replace with 
a spare LP gas tank and resume burning. Store a spare LP gas 
tank in a well ventilated area away from children.

If problems can not be corrected by using these methods, please contact 1.800.762.1142 for assistance.

Summary of Contents for GLT905W

Page 1: ...re created by the combustion of propane WARNING FOR YOUR SAFETY For Outdoor Use Only outside any enclosure Do Not Use For Cooking WARNING FOR YOUR SAFETY If the information in this manual is not follo...

Page 2: ...creational vehicles Always use in accordance with all applicable local state and national codes Contact your local fire department for details on outdoor burning When using this outdoor fire bowl exer...

Page 3: ...834 3 Pilot 55 05 835 4 Burner 55 05 836 5 Bowl 55 05 837 6 Body 55 05 838 7 Valve Assembly 55 05 839 8 Valve Bracket 55 05 840 9 Control Knob 55 05 841 10 Regulator 55 05 842 11 Regulator Bracket 55...

Page 4: ...ou will need 1 Leak Detection Solution Instructions on how to make solution are included in Operating Instructions Note You must follow all steps to properly assemble outdoor fire bowl Assembly Instru...

Page 5: ...t light burner use a long match or long butane lighter Illustration 3 a Wearing Heat reistant gloves position the lit long match or lit long butane lighter near the side of the burner b Turn control k...

Page 6: ...y third party or failure to perform normal and routine maintenance on the product as set out in this owner s manual In addition the Limited Warranty does not cover damage to the finish such as scratch...

Page 7: ...ean burner ports Sudden drop in gas flow or reduced flame height Out of gas Check for gas in the LP gas tank Excess flow safety device may have been activated Turn control knob to OFF wait 30 seconds...

Page 8: ...LP Gas Outdoor Fire bowl Model No GLT905W...

Page 9: ...Chimenea de propano para exteriores modelo n GLT905W...

Page 10: ...gas en el tanque de propano l quido Puede que se haya activado el dispositivo de seguridad de exceso de flujo Gire la perilla a la posici n OFF apagado espere 30 segundos y encienda la chimenea para e...

Page 11: ...usuario Adem s la garant a limitada no cubre da os al terminado de la unidad tales como rasgu os abolladuras descoloridos oxidaciones y otros da os causados por la intemperie despu s de la compra de...

Page 12: ...ncendida o un encendedor de butano largo encendido cerca de un costado del quemador b Gire la perilla de control en la direcci n contraria a las manecillas del reloj a la posici n HIGH encendido c Rem...

Page 13: ...os pasos pare armar correctamente la chimenea para exteriores Instrucciones de armado 2 Coloque las piedras volc nicas Instalaci n del tanque de gas propano l quido Para hacer funcionar la chimenea ne...

Page 14: ...05 835 4 Quemador 55 05 836 5 Cuenco 55 05 837 6 Carcasa 55 05 838 7 Conjunto de v lvula 55 05 839 8 Soporte de la v lvula 55 05 840 9 Perilla de control 55 05 841 10 Regulador 55 05 842 11 Soporte d...

Page 15: ...teriores en embarcaciones o veh culos de recreo Observe siempre y use la unidad cumpliendo todos los c digos de incendio aplicables locales y nacionales Obtenga de su Departamento de Incendios local d...

Page 16: ...s u otros da os reproductivos ADVERTENCIA PARA SU SEGURIDAD Solamente para uso en exteriores fuera de cualquier recinto No use esta unidad para cocinar adentro ADVERTENCIA PARA SU SEGURIDAD El no segu...

Reviews: