8
6.4 Setting Detail Chart
Object
Setting
Range
Default
Notes
LOCK/
UNLOCK
NO/YES
0
LOCK
NO
0.0-100V
0.0-100V
100V
0-Range
maximum
0.0V
Range maxi
mum
0.0-99.9V
0.0V
01ZV
(Zero Capacity
voltage)
02OV
(Over Voltage
Alarm)
Alarm)
Alarm)
Alarm)
03OC
(Over Amperage
04LV
(Low Voltage
05LB
(Low Capacity
06HT(High
Temperature
Alarm)
07VC
(Voltage
Fine-tuning)
08CC
(Amperage
Fine-tuning)
09CZ
(Zero Amperage
Adjust)
10TC
(Temperature
Fine-tuning)
11CA
(Battery Actual
Capacity)
12FV
(Full Capacity
Voltage)
13LK
(Menu Lock)
14DF
(Reset Default
Setting)
0
-
100%
-9 - 99
℃
0%
99
℃
When the battery voltage is lower than this value,
the capacity would be set to 0%.
When the battery voltage is higher than this value and the
voltage number flashes, the beeper rings every 0.5s.
When the battery amperage is higher than this value and the
amperage number flashes, the beeper rings every 0.5s.
When the battery voltage is lower than this value and the
voltage number flashes, the beeper rings every 0.5s.
When the battery capacity is lower than this value and the capacity
percentage and the battery icon flashes, the beeper rings every 0.5s.
When the battery temperature is higher than this value and the
temperature number flashes, the beeper rings every 0.5s.
(This model does not equipped with this function).
When the displayed voltage does not fit the actual voltage,
it can be fine-tuned within certain range.
When the displayed amperage does not fit the actual amperage,
it can be fine-tuned within certain range.
When the battery is empty but the amperage is not at “0”,
it needs to be adjusted.
When the displayed temperature does not fit the actual
temperature, it can be fine-tuned within certain range.
(This model does not equipped with this function).
Object 01-12 can only be adjusted when the menu lock is on.
Choose “YES” to reset all the setting to default.
Battery’s actual capacity.
When the battery voltage is higher than this value, the capacity
percentage would be set to 100%. (Only works in “Manual-mode”).