PROBLEM
PROBLEM CAUSED
‘
Restraint Arm Blocked
’
Followed by:
‘
Restore Restraint, press ‘SEL’ to continue, Blue Genius™ Warning
’
(repeats)
Restraint arm failed to lower all the way down. Check for debris.
Faulty IPS board.
‘
Restraint is Engaged
’ followed by: ‘
Dock Leveler Restored
’, ‘
Ready to
Deploy Deck
’. (repeats)
The Engaged button has been touched and vehicle restraint is in locked
position.
During self test mode the following message appears: ‘
Remote I/O Bad
’
Faulty wiring, check communication cable wires for loose connections.
Remote I/O is faulty, replace.
Blue Genius™ power board is faulty, replace.
During self test mode the following message appears: ‘
Positioner Bad
’
Faulty wiring, check communication cable wires for loose connections.
IPS board is faulty, replace.
Blue Genius™ power board is faulty, replace.