12
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Operation Tips
•
Note:
Test the GFCI before each use:
1. Plug GFCI into power outlet. Indicator should turn
green to show that cord has power.
2. Press test button, green indicator should turn off
to verify that GFCI cut off power to the cord.
3. Press reset button – green indicator should turn
on to show that cord has power again.
4. When GFCI is working properly, green indicator
will turn on when power is applied. If green
indicator turns off, it has detected electric leakage
and the GFCI cut off power to theappliance.
• If you hear the motor run intermittently when the
trigger is not being squeezed, that is normal. The
pump is priming itself so it is ready to operate when
the trigger is squeezed. Turn off the power washer if
not being used after five minutes.
• The o-rings on the bayonet end of the nozzle lance
should be cleaned regularly and lubricated with non-
water soluble grease such as petroleum jelly.
• Keep the nozzle cleaning wire for use in unclogging
the nozzle. If you lose the cleaning wire, a
straightened paper clip also works.
How to Avoid Damaging Surfaces
• Damage to surfaces being cleaned occurs because
the impact force of the water pressure exceeds
the durability of the surface. Bare wood can be
penetrated; paint can be peeled off, etc. You can
vary the force of your power washer by controlling:
1. The angle of the surface being cleaned.
2. The distance of the nozzle from the surface being
cleaned.
•
NEVER
use a narrow high pressure stream of water
on soft surfaces susceptible to damage.
Adjusting Soap Levels on Foam Cannon
Twist knob to adjust the level of soap as indicated on
the top of the Foam Cannon (H). Twist toward the higher
concentration of bubbles for more soap, or the opposite
direction for less.
H
F
95499_IM_BC 142 HS_ENG-FR-SP.indd 12