VARIOLITE Small Form Factor PC
User Guide - Specification
Page 9
System Management:
CPU temperature monitoring, system temperature monitoring, CPU fan speed
monitoring and voltage monitoring of Vcore, +3.3V, +5V, +12V, -12V and Vbat
are all available to the application for monitoring and reporting.
Power Requirements:
Auto-ranging 115 - 230V / 4 – 2A / 60 - 50Hz, with IEC320 power inlet.
Power Consumption
93W (CPU Usage constant 100%)
66W (CPU Usage variable 30-55%)
34W (CPU Usage 0%)
Measurements taken on Windows XP Professional
Environmental Conditions:
Operating temperature range +5 ºC to +40 ºC in free air.
Storage temperature range -20 ºC to +70 ºC
Relative Humidity 10-85% non-condensing.
Shock and vibration compatible with light industrial usage.
Note: if product is stored below 0 ºC, then it should be brought up above 5 ºC
before powering on or damage may result to the HDD
Construction:
Painted zinc-plated sheet steel, welded construction.
Dimensions:
300 x 246 x 50 mm, excluding the earth (ground) stud and the mounting
brackets.
Note that an additional 60 mm will be required to the rear of the chassis to allow
easy access to the cable connectors.
Air vents must not be obstructed. A minimum gap of 25 mm between vents and
any adjacent items is recommended.