2021-11
1 866 907 0122 blubathworks.com
1
2
QRI-0910 Thermostatic Mixing Valve
1.
Let water flow for at least two minutes to allow supply temperature to stabilize.
2.
Calibrate the mixed water outlet temperature by placing a thermometer in the mixed water stream.
3.
To adjust the setting of the valve, loosen locking cap screw with hex wrench (refer to Figure 3)
Cap must be lifted 1/4” to adjust temperature. To increase the temperature, turn counterclockwise.
To decrease temperature turn clockwise.
4.
Lower handle and tighten screw.
5.
Check outlet temperature.
Summary of Contents for INOX QRI-0030
Page 6: ...2021 11 1 866 907 0122 blubathworks com 5 Attention Placement in wall QRI 0001 rough in valve...
Page 9: ...2021 11 1 866 907 0122 blubathworks com 8 QRI 0001...
Page 12: ...2021 11 1 866 907 0122 blubathworks com 11 QRI 0910 Thermostatic Mixing Valve...
Page 15: ...2021 11 1 866 907 0122 blubathworks com 14 QRI 0910 Thermostatic Mixing Valve...
Page 16: ...2021 11 1 866 907 0122 blubathworks com 15 QRI 0910...