background image

 

FLOOR STANDING WATER BOILERS 

MOD. SIMPLEX 

n.1460080EN 07-2009 

 

                                                                                                                                                                        

BUILDING CHARACTERISTICS 

 

The 

SIMPLEX 

boilers are pressurized combustion heat exchangers made of steel with inversion flame 

type and successive turn in the tube system. 

The high speed of the fumes inside the tubes and the high turbolence provoked with the new 

TURBOLATORS IN STAINLESS STEEL AISI 

430, favours the heating exchange, decreases of the 

consumption, increasing the combustion yeld that reachs an efficiency over 90%. 

The jacket consists of elegant panels in steel painted with epoxy powder paint, and is totally insulated 
with rock wool in order to give it high an heat insulation characteristics. 

The power losses on the smoke side are so limited as the allow a wide range of choice for operation 
with gas oil-fire burners with forced air. 
 

The front door hinge-mounted it’s insulated inside with ceramic fiber to be resistant high temperature 
and take the functions: 

§

 

fumes reversal chamber 

§

 

furnace and tube system inspection and cleaning 

§

 

burner support 

 
The control panel is complete with all the instruments necessary  to optimise the control and the 

correct operation of the boiler. 
The boiler body is made of iron and completely is welded with procedure mag (metal-arc active gas), 
arc welding in active gas atmosphere with electrode fuse. 

In order to ensure maximum quality and reliability over time, all the boilers are subjected to testing 
under severe conditions during all the phases of the production. 

The shelves are checked and tested hydraulically at 4,5 bar. 
The maximum working pressure is 3 bar. 
 

 
 
 
 

 
 
 
 

 

Summary of Contents for SIMPLEX 35

Page 1: ...INSTRUCTIONS MANUAL FOR BOILERS MODELS SIMPLEX 35 SIMPLEX 50 SIMPLEX 80 n 1460080 EN Upd 01 07 09...

Page 2: ...FLOOR STANDING WATER BOILERS MOD SIMPLEX n 1460080EN 07 2009 2...

Page 3: ...INDEX 1 IMPORTANT 3 2 BUILDING CHARACTERISTICS 4 2 1 TECHNICAL DATA 5 2 2 CONTROL PANEL 6 3 INSTALLATION 7 3 1 BURNERMATCHING 7 3 2 OPERATING 7 4 MAINTENANCE 8 5 WIRING DIAGRAM 9...

Page 4: ...ate a hazard The Manufacturer cannot be held liable for damage caused by improper or unreasonable use q Before cleaning or servicing the boiler disconnect from the power mains by operating the switch...

Page 5: ...n the smoke side are so limited as the allow a wide range of choice for operation with gas oil fire burners with forced air The front door hinge mounted it s insulated inside with ceramic fiber to be...

Page 6: ...ar 3 3 3 Combustion s chamber lenght mm 400 490 540 Combustion s chamber volume dm 3 27 2 35 8 53 3 Smoke discharge mm 127 127 127 Smoke s exit temperature C 153 153 156 Combustion chamber pressure Pa...

Page 7: ...OILERS MOD SIMPLEX n 1460080EN 07 2009 6 2 2 CONTROL PANEL A Timer optional E Switch on off B Heating regulation thermostat F Heating thermometer C Safety thermostat manual reset G Hydrometer D Fuse H...

Page 8: ...the wiring suitable for the equipment and burner maximum power adsorption 3 1 BURNER MATCHING For installation of the burner the electrical connections and the necessary settings consult the burner i...

Page 9: ...uits the combustion chamber The fumes range cleaning it s more important only millimetres of soot increase the flue gas outlet temperature at least 30 C decreasing one percentage point of thermal effi...

Page 10: ...Phase LO Programming time phase TA Environment Thermostat optional CO Programming time contact F Fuse TM Anti condensation low point thermostat CR Heating circulating pump IL Switch on off BR Burner I...

Page 11: ...134 PADOVA ITALY Tel 39 049 601600 Fax 39 049 9301471 Technical specifications and measurements are not binding The Company reserves the right to make changes without prior notice We decline all respo...

Reviews: