OPERATION
CAUTION:
HOT SURFACE
Exposed surfaces can be hot
to the touch and may cause
burns.
VENTILATOR OPERATION
1. Press the VENTILATOR POWER switch to ON. The green
VENTILATOR POWER
light will glow and the blower fan will start.
After a short time, if all filters are sensed as being in position and
not clogged, the cooktop will be energized. The roll warmer is
energized at all times.
During normal operation, the
VENTILATOR POWER
light will be
the only light glowing on the upper control panel.
2. If the amber
CHECK FILTER
light glows, one or more filter
elements is out of position. Check the GREASE BAFFLE,
PRE-FILTER and FILTER PACK for proper installation in their
respective positions. Grease baffle and filter pack position are
sensed by mechanical switches. Pre-filter position is sensed by a
vacuum
switch.
3. When the amber
REPLACE PRE-FILTER
light glows, the pre-filter
is nearing the end of its service life. Replace the disposable
PRE-FILTER
ELEMENT.
4. When the amber
REPLACE FILTER PACK
light illuminates, the
HEPA / Charcoal filter pack is nearing the end of its service life.
Replace the FILTER PACK.
Note:
The
REPLACE PRE-FILTER
and
REPLACE FILTER PACK
lights are a warning that the indicated filter is near the end of its
service life. The appliance will continue to operate for a period of
time after the light glows to allow continued operation through a
peak period. However, the indicated filters must be replaced within
a reasonably short time period or they will clog and shut down
electrical power to the cooktop. The ventilator blower will continue
to
run.
5. When the red
SERVICE REQUIRED
light glows, either the
pre-filter or filter pack (or both) is clogged and can no longer pass
sufficient air to allow further operation. The ventilator fan continues
to run, but the cooktop is shut down until the underlying clogged
filter situation has been corrected. This can occur when neither
CHANGE...FILTER
indicator light is lit, if both pre-filter and filter
pack are marginal. Replacing both the pre-filter and the filter pack
will remedy the situation.
Note:
replacing the pre-filter, even though not very dirty, will often
extend the service life of the more expensive filter pack.
Reset the unit by turning the
VENTILATOR
POWER
switch to
OFF
, then back
ON
.
6. A failure of incoming electrical power will cause a shut down of the
unit. After power is restored, reset the unit by turning the
VENTILATOR PO
WER switch to
OFF
, then back
ON
.
Fig. 9 Ventilator Indicator
and
Warning
Lights
13
504
p/n
3039
03
o
p
M
W
V
-4H V
entle
ss Ho
tpla
te Coo
k
top