INSTALLATION INSTRUCTIONS
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
Unpack the unit. Inspect all components for completeness and
condition. Ensure that all packing materials have been removed
from the unit.
Verify that the Spray Head Gasket and Spray Disk are properly
installed.
LEVELING THE UNIT
Verify that an adjustable leg is installed at each corner of the
brewer.
Set brewer in its operating location. Level the brewer. A spirit
level should be placed on the top of the unit, at the edge, as a
guide when making level adjustments.
Level the unit from left to right and front to back by turning the
adjustable feet. Be sure all four feet touch the counter to prevent
tipping.
PLUMBER’S INSTALLATION INSTRUCTIONS
Brewer should be connected to a
POTABLE WATER, COLD
WATER
line. Flush water line before connecting to brewer.
DO NOT use a saddle valve with a self-piercing tap for the water
line connection. Such a tap can become restricted by waterline
debris. For systems that must use a saddle tap, shut off the main
water supply and drill a 3/16” (minimum) tap for the saddle
connection, in order to insure an ample water supply. Remember
to flush the line prior to installing the saddle.
The brewer must be installed on a water line with average
pressure between 20 PSI and 90 PSI. If your water pressure
exceeds 90 PSI at anytime, a pressure regulator must be
installed in the water supply line to limit the pressure to not more
than 90 PSI in order to avoid damage to lines and solenoid.
A water shut-off valve should be installed on the incoming water
line in a convenient location (Use a low restriction type valve,
such as a 1/4-turn ball valve, to avoid loss of water flow thru the
valve.
NSF requires that the brewer be able to be moved for cleaning
underneath. A flex line or loops of copper tubing will satisfy this
requirement. See Figure 2 below.
IMPORTANT:
To enable the installer to make a
quality installation and to mini-
mize installation time, the follow-
ing suggestions and tests should
be done before the actual unit
installation is started:
CAUTION:
EQUIPMENT DAMAGE
DO NOT plug in or energize this
appliance until all Installation
Instructions are read and
followed.
Damage to the Brewer will occur
if these instructions are not
followed.
CAUTION:
UNSTABLE
EQUIPMENT HAZARD
It is very important for safety and
for proper operation that the
brewer is level and stable when
standing in its final operating po-
sition. Provided adjustable, non-
skid legs must be installed at
each corner of the unit. Failure
to do so will result in movement
of the brewer which can cause
personal Injury and/or damage to
brewer.
NOTE:
Water supply inlet line
must meet certain minimum
criteria to insure successful
operation of the brewer.
Bloomfield recommends 1/4" cop-
per tubing for installation of less
than 12 feet and 3/8" for more
than 12 feet from a 1/2" water
supply line.
4
Fig. 2 Water Supply
Installation
601
75815
Owner
s
M
anual In
tegri
ty Decante
r B
rewers