background image

601  

75815

  Owner

M

anual In

tegri

ty Decante

r B

rewers 

NOTE:  

For your protection, please note that equipment in 

this shipment was carefully inspected and packaged by 
skilled personnel before leaving the factory.   
Upon acceptance of this shipment, the transportation       
company assumes full responsibility for its safe delivery.

 

IF SHIPMENT ARRIVES DAMAGED:

 

1.

 

VISIBLE LOSS OR DAMAGE:

    Be  certain  that  any 

 

visible  loss  or  damage  is  noted  on  the  freight  bill  

 

or express receipt, and that the note of loss or damage 

 

is signed by the delivery person. 

2. 

FILE CLAIM FOR DAMAGE IMMEDIATELY: 

 

  

Regardless of the extent of the damage. 

3. 

CONCEALED LOSS OR DAMAGE: 

 if damage is 

        unnoticed until the merchandise is unpacked, notify the           
        transportation company or carrier immediately, and file    
        “CONCEALED DAMAGE” claim with them.  This 
        must be done within fifteen (15) days from the date the  
        delivery was made to you.  Be sure to retain the 
        container for inspection. 

 

Wells Bloomfield cannot assume liability for damage or loss 
incurred in transit.  We will, however, at your request, supply 
you with the necessary documents to support your claim. 

WARRANTY STATEMENT 

SERVICE POLICY AND PROCEDURE GUIDE 

ADDITIONAL WARRANTY EXCLUSIONS 

SHIPPING DAMAGE CLAIMS PROCEDURE 

1.     Resetting   of  safety  thermostats,  circuit breakers,  
 

overload protectors, or fuse replacements  unless       

 

warranted conditions are the cause. 

2.  All problems due to operation at voltages other than 
 

specified on equipment nameplates; conversion to 

 

 

 

 

 

correct voltage must be the customer’s responsibility. 

3.    All problems due to electrical connections not made in 
 

accordance  with  electrical  code  requirements  and  

 

wiring diagrams supplied with the equipment. 

4.     Replacement of items subject to normal wear, to include 
 

such items as knobs and light bulbs.  Normal maintenance 

 

functions including adjustment of thermostats, microswitches, 

 

and replacement of fuses and indicating lights are not 

 covered 

under 

warranty. 

5.     All problems due to inadequate water supply, such as 
 

fluctuating, or high or low water pressure. 

6.   All  problems  due  to  mineral/calcium  deposits,  or        
 

contamination from chlorides/chlorines. De-liming is 

 

 

 

considered a preventative maintenance function and is 

 

not covered by warranty. 

All 

electrical 

equipment 

manufactured 

by 

WELLS         

BLOOMFIELD, LLC is warranted against defects in materials 
and workmanship for a period of one year from the date of 
original installation or eighteen (18) months from the date of 
shipment from our factory, whichever comes first, and is for 
the benefit of the original purchaser, except that: 
a.     airpots carry a 30 day parts warranty only. 
b. 

dispensers; i.e., tea and coffee carry a 90  days parts      

        warranty only, excludes decanters. 

 
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN 
LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR 
IMPLIED,  INCLUDING  ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE, WHICH ARE HEREBY EXCLUDED.   
 
WELLS BLOOMFIELD, LLC SHALL NOT  BE  LIABLE  
FOR  INDIRECT,   INCIDENTAL  OR  CONSEQUENTIAL    
DAMAGES 

OR 

LOSSES 

FROM 

ANY 

CAUSE                

WHATSOEVER. 
 
This warranty is void if it is determined that upon inspection by 
an Authorized Service Agency that the equipment has been 
modified, misused, misapplied, improperly installed, or 

 

 

 

 

damaged in transit or by fire, flood or act of God. 

It also does not apply if the serial nameplate has been       
removed or unauthorized service personnel perform service.  
The prices charged by Bloomfield Industries for its products 
are based upon the limitations in this warranty.  Seller’s     
obligation under this warranty is limited to the repair of defects 
without charge by a Bloomfield Authorized Service Agency or 
one of its sub-agencies.  This service will be provided on   
customer’s premises for non-portable models.  Portable 

 

 

models (a device with a cord and plug) must be taken or 
shipped to the closest Authorized Service Agency, transporta-
tion charges prepaid, for services. 

 
In addition to restrictions contained in this warranty, specific 
limitations are shown below (Additional Warranty Exclusions).  
Bloomfield Industries Authorized Service Agencies are located 
in principal cities. 

 
This warranty is valid in the United States and void elsewhere.  
Please consult your classified telephone directory or your food 
service equipment dealer; or, for information and other details 
concerning warranty, write to: 

 

Service Parts Department 

Wells Bloomfield, LLC 

P.O. Box 280 

Verdi, NV  89439 

  Phone:  (775) 689-5707 

 

Fax: (775) 689-5976

 

  7.   Full use, care and maintenance instructions are supplied 
 

with each machine.  Those miscellaneous adjustments 

 

noted are customer responsibility.  Proper attention will 

 

prolong the life of the machine. 

  8.  Travel  mileage is limited to  sixty (60)  miles from an   
 

authorized Service Agency or one of its sub-agencies. 

  9.   All labor shall be performed during normal working hours.  
 

Overtime premium shall be charged to the customer. 

10.   All genuine Bloomfield replacement parts are warranted 
 

for ninety (90) days from date of purchase on non-

 

warranted equipment.  

Any use of non-genuine 

 

 

Bloomfield parts completely voids any warranty

11.  Installation, labor and job check-out are not considered 
 warranty. 
12.  Charges incurred by delays, waiting time or operating 
 

restrictions  that  hinder  the  service  technicians  ability  

 

to  perform services  are  not  covered  by  warranty.  

 

This  includes  institutional and correctional facilities. 

xi 

Summary of Contents for Integrity 9010

Page 1: ... telephone 775 689 5707 fax 775 689 5976 www wellsbloomfield com p n 75815 Rev F ECN 13387 M601 071112 cps OWNERS MANUAL for INTEGRITY DECANTER COFFEE BREWERS MODELS 9010 9012 9016 Includes Installation Use Care Servicing Instructions Model 9012 Brewers with optional 8900 Series Glass Decanters 601 ...

Page 2: ...ry a 30 day parts warranty only b dispensers i e tea and coffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY EXCLUDED WELLS BLOOMFIELD LLC SHALL NOT BE LIABLE FOR INDIRECT INCIDENTAL OR CONS...

Page 3: ...G CONTROLS 2 PRECAUTIONS GENERAL INFORMATION 3 AGENCY APPROVAL INFORMATION 3 INSTALLATION INSTRUCTIONS 4 OPERATION 6 BREWING COFFEE 8 CLEANING INSTRUCTIONS 9 TROUBLESHOOTING SUGGESTIONS 10 SERVICING INSTRUCTIONS 11 Deliming Instructions 16 EXPLODED VIEWS PARTS LISTS 18 WIRING DIAGRAMS 22 SPECIFICATIONS 1 MODEL STYLE VOLTS WATTS AMPS 1ø POWER SUPPLY CORD 9010 3W IN LINE FAUCET 120 2300 19 NEMA 5 20...

Page 4: ...FEATURES AND OPERATING CONTROLS Fig 1 Features Operating Controls 2 601 75815 Owners Manual Integrity Decanter Brewers ...

Page 5: ...ce is intended for use in commercial establishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must be read and understood by all operators and users Except as noted this piece of equipment is made in the USA and has American sizes on hardware All metric conversions are approximate and can vary in size The followin...

Page 6: ... the water supply line to limit the pressure to not more than 90 PSI in order to avoid damage to lines and solenoid A water shut off valve should be installed on the incoming water line in a convenient location Use a low restriction type valve such as a 1 4 turn ball valve to avoid loss of water flow thru the valve NSF requires that the brewer be able to be moved for cleaning underneath A flex lin...

Page 7: ...d IMPORTANT Before connecting to electricity make sure automatic brewers are connected to the water supply Models 9010 9012 are equipped with a cord and plug They require a 115 125 volt 20 amp circuit 50 60 Hz 2 wire plus ground with NEMA 5 15R or 5 20R Receptacle IMPORTANT The ground prong of the plug is part of a system designed to protect you from electrical shock in the event of internal damag...

Page 8: ...ift the pour over cover then pour warm tap water into the pour over opening until water flows from the brew head When water stops dripping from the brew head empty the container Once the tank is full of water connect the brewer to electrical power The heating elements will begin heating the water in the tank When the water has reached the proper temperature the HEAT light will go out IMPORTANT Tan...

Page 9: ...BREW button energizes the solenoid valve allowing water from an external water supply to flow into the basin pan and then into the hot water tank This forces an identical amount of hot water out of the tank and through the spray head into the brew chamber The solenoid uses a flow control device so that flow is consistent between 20 p s i and 90 p s i Length of time the solenoid is open is controll...

Page 10: ...ntents of the decanter into the pour over opening which will fill the basin Water from the basin will displace a like amount of heated water from the tank The hot water will be forced into the brew head where it will spray over the bed of grounds Freshly brewed coffee will begin to fill the container under the brew chamber When the flow and all dripping stops the coffee is ready to serve Discard t...

Page 11: ...ray holes Rinse the spray disk with clean water and allow to air dry 7 Wash the brew chamber in a sink using warm water and a mild detergent A bristle brush may be used to clean the inside Rinse with clean water and allow to air dry For stainless steel brew chambers be sure the wire rack is properly reinstalled 8 Wipe the exterior of the brewer with a soft clean cloth or sponge moistened with clea...

Page 12: ... tripped Damaged internal component or wiring No water or too little water added at start up Not enough water poured in Too much coffee grounds Timer out of adjustment Too many filter papers or wrong filter paper Brew chamber dispense hole plugged Too much coffee or too fine a grind Spray gasket missing or improperly installed Spray disk plugged Water supply OFF Water line strainer plugged Water f...

Page 13: ...ining lip IN LINE BREWERS Top panel is held by two screws at the rear and a retaining lip at the front Disconnect wires from the upper warmers Top front panel is held by two screws at the bottom and a retaining lip at the top Bottom front panel is held by two clips under the warmer plate CAUTION SHOCK HAZARD Opening access panels or removing warmer plates on this brew may expose uninsulated electr...

Page 14: ...posed electrical circuits These procedures are to be performed by qualified technical personnel only NOTE Optimum brewing temperature range is 195ºF to 205ºF 90ºC to 96ºC IMPORTANT A mechanical thermostat will maintain temperature within 5ºF To prevent boiling water in the brewer thermostat should be adjusted to a maximum temperature equal to the local boiling temperature minus 5ºF NOTE 1 8 turn a...

Page 15: ...es to check amount of water delivered Replace button plug REMOVE TANK LID ASSEMBLY Unplug brewer or turn circuit breaker OFF Turn OFF water supply Remove top panel Pull vent tube and inlet elbow out of basin pan Pull water inlet tube out of basin pan Remove basin pan On models with faucet disconnect inlet pipe at faucet shut off valve and outlet pipe at faucet Disconnect all wiring from thermostat...

Page 16: ... extreme end of the metal hose fitting b Pressure on the white ring toward the metal ferrule releases the clinch ring allowing the hose to be easily slid off of the solenoid bypass outlet c Install hose on new valve by pressing end of hose onto bypass outlet until it is fully seated Disconnect wiring Remove two screws holding solenoid to access door Reassemble in reverse order CLEAN SOLENOID SCREE...

Page 17: ...ead except when faucet valve is turned OFF Remove tank lid assembly per above Remove two hex nuts hot water coil to cover Pull coil from mounting holes Reassemble in reverse order REPAIR HOT WATER FAUCET Remove top panel and turn faucet valve OFF Unscrew aerator cap from faucet and remove handle retaining clip Do not let faucet body turn Pull bonnet assembly from faucet body Examine the interior o...

Page 18: ...isconnect brewer from the electrical supply Turn off the water shut off valve and disconnect the water supply line from the brewer inlet fitting 2 Remove the tank lid assembly as described on page 13 3 Remove the water tank from the brewer body by lifting straight up Empty all water from the tank Set the tank back into the brewer 4 Mix 2 quarts of deliming solution according to the manufacturer s ...

Page 19: ...ll internal components are dry then reinstall the top panel 10 Reconnect brewer to electrical supply and for automatic brewers reconnect water supply 11 Install the brew chamber without filter paper or grounds Run at least three full brew cycles and discard all water generated 12 Brewer is ready to use NOTE Normally silicone hoses do not need to be delimed Should deliming hoses become necessary Bl...

Page 20: ...16 EX 60 8043 15 TUBE VENT SILICONE 9010 9012 CA 9016 EX 61 8043 11 ELBOW TANK OUTLET SILICONE 9010 9012 CA 9016 EX 63 8043 83 8552 50 THERMOSTAT HI LIMIT THERMOSTAT HI LIMIT RESET 9012 CA 9010 9016 EX 66 8043 24 WATER INLET TUBE 9010 9012 CA 9016 EX 67 8043 93 8043 14 8716 1 HEATING ELEMENT 120V 1200W HEATING ELEMENT 120V 1500W HEATING ELEMENT 240V 3500W 9012CA 9010 9012 9016 9016EX 68 8043 10 TA...

Page 21: ... SEMS FAUCET 9010 9012 CA 9016 EX 28 82681 WASHER FLAT 15 32 x 1 1 8 x 1 16 SS 9010 9012 CA 9016 EX 29 82556 FAUCET ASSEMBLY PRESSURE 9010 9012 CA 9016 EX 33 8543 42 GASKET SPRAY HEAD 9010 9012 CA 9016 EX 34 82727 SPRAY DISK EMBOSSED 9010 9012 CA 9016 EX 34a 8543 45 RETAINER SPRAY HEAD REQUIRES DRILL RIVETS TO INSTALL 9010 9012 CA 9016 EX 43 8541 46 TUBE BASIN INLET SILICONE 13 9010 9012 CA 9016 E...

Page 22: ... ASSEMBLY 120V NEMA 5 15P 9010 9012 CA 37 35 210 STRAIN RELIEF 9010 9012 CA 43 8552 18 TERMINAL BLOCK 4P 9016 EX 45 85685 84570 SOLENOID W BYPASS 120V 75 GPM SOLENOID W BYPASS 220 240V 75 GPM 9010 9012 CA 9016 EX 50 8512 51 86280 THERMOSTAT BLACK BODY INCL SEAL MOUNTING SCREWS THERMO ALT GRAY BODY INCL TUBE MOUNTING SCREWS 9010 9012 CA 9016 EX 63 8043 83 8552 50 THERMO HI LIMIT THERMO HI LIMIT RES...

Page 23: ...9010 9012 CA 9016 EX 105 86666 POUR OVER ASSEMBLY PLASTIC 9010 9012 CA 9016 EX 107 9012 28 SPLASH GUARD POUR OVER 9010 9012 CA 9016 EX 108 8541 21 BASIN PAN 9010 9012 CA 9016 EX 121 9012 11 9016 211 BODY BASE ASSEMBLY BODY BASE ASSEMBLY EXPORT 9010 9012 CA 9016 9016 EX 123 9012 6 PANEL LOWER FRONT 9010 9012 CA 9016 EX 124 9012 23 BOTTOM PLATE 9010 9012 CA 9016 EX 125 8543 80 CLIP MOUNTING 9010 901...

Page 24: ...AIN WARMER TOP REAR WARMER TOP FRONT WARMER MODEL 9012 WHITE 2 2 1 1 2 1 3 3 3 LINE 1 120V LINE 2 NEUT GROUND 1 ELEMENT p n 71725 1 2 3 1 2 3 1 2 3 READY LIGHT BREW SWITCH WARMER SWITCH WARMER SWITCH WARMER SWITCH SOLENOID THERMOSTAT TIMER ORANGE ORANGE BLACK BLACK 14ga 14ga 14ga 14ga BLACK BLACK BLACK RED GREEN WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE BLUE BROWN BROWN MAIN WARMER TOP REAR ...

Page 25: ...ga ORANGE ORANGE MAIN WARMER TOP REAR WARMER TOP FRONT WARMER C1 A1 A2 C2 C3 B1 B2 B3 A4 HI LIMIT BLACK BLACK BLACK 12 ga 12 ga 12 ga THERMOSTAT ELEMENT p n 72356 TIMER GREEN 1 2 3 1 2 3 1 2 3 READY LIGHT BREW SWITCH WARMER SWITCH WARMER SWITCH WARMER SWITCH SOLENOID BROWN 12 ga BROWN 12 ga BROWN BROWN MODEL 9016EX MAIN WARMER TOP REAR WARMER TOP FRONT WARMER B2 THERMOSTAT ELEMENT p n 73652 A4 B1 ...

Page 26: ...TION CUSTOMER SATISFACTION Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association Commercial Food Equipment Service Association PRINTED IN UNITED STATES OF AMERICA WELLS BLOOMFIELD LLC 2 ERIK CIRCLE P O Box 280 Verdi NV 89439 telephone 775 689 5707 fax 775 689 5976 www wellsbloomfield com ...

Reviews: