TERMINAL
BLOCK
FRONT
PANEL
IL1717
INSTALLATION INSTRUCTIONS (continued)
NOTE:
This equipment must
be installed to comply with
applicable federal, state and
local plumbing codes and
ordinances.
WARNING:
SHOCK HAZARD
Brewer must be properly
grounded to prevent possible
shock hazard. DO NOT assume
a plumbing line will provide
such a ground. Electrical shock
will cause death or serious
injury.
IMPORTANT:
Do not connect
brewer to electrical power until
ERWKWDQNVDUH¿OOHGZLWKZDWH
r.
Pour water into each pour-over
RSHQLQJXQWLOZDWHUÀRZVIURP
the respective brew head.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
brewer or result in decreased
performance. Such damage is
not covered by warranty.
NSF requires that the brewer be able to be moved for cleaning
underneath. A
ÀH[OLQHRUORRSVRIFRSSHUWXELQJZLOOVDWLVI\WKLV
requirement. See Figure 2 below.
,QVRPHDUHDVORFDOFRGHVUHTXLUHDEDFNÀRZSUHYHQWHU
(check
YDOYHWREHLQVWDOOHGRQWKHLQOHWZDWHUOLQH,IDEDFNÀRZ
preventer is used, you must install a
water hammer arrester
LQWKHLQFRPLQJOLQHEHWZHHQWKHEDFNÀRZSUHYHQWHUDQGWKH
brewer inlet, as far away from the brewer as space will allow.
7KLVZLOOUHOLHYHWKHH[FHVVLYHEDFNSUHVVXUHVWKDWFDQFDXVH
faucet leaks and solenoid malfunctions.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
IMPORTANT:
Before connecting to electricity, make sure
automatic brewers are connected to the water supply.
Gourmet 1000™ dual brewers
must be wired by an electrician.
Model 8792 requires a 120/240V 20A circuit (50/60 Hz, L1, L2,
Neut. plus Ground).
Remove front panel to gain access to terminal block. Green
terminal must be connected to a suitable building ground. Circuit
must be capable of 4000 W
DWWV6HH¿JXUHDWULJKW
IMPORTANT:
Wiring must be installed in approved solid or
ÀH[LEOHFRQGXLWDQGPXVWEHVHFXUHGWRWKHEUHZHUZLWKDVWUDLQ
relief (to be provided by the installer).
Fig. 3 115/230 Volt Terminal Block
Fig. 2 Water Supply Installation
5
COPPER LOOPS OR FLEX LINES
(PROVIDED BY PLUMBER)
NOTE DUAL 1/4”
FEMALE FLARE FITTINGS
(PROVIDED BY PLUMBER)
WATER
SUPPLY
FLOW
SOLENOID
STRAINER
WASHER
INLET
FITTINGS
SHUT-OFF VALVE
(PROVIDED BY
PLUMBER)
IL1716
Brewer mu
W
S
Brewer mu
WARNING
625 p/n 2M-75873 8792, 8793 Dual Coffee Brewer