PRECAUTIONS AND GENERAL INFORMATION 

E6070 

AGENCY LISTING INFORMATION 

Refer to the 

product nameplate 

for the specific appliance for agency 

listings.  In general: 

 
This appliance conforms to NSF Standard 4 for sanitation only if        
installed in accordance with the supplied 

Installation Instructions. 

 

UL Listed warmers are 

U

 Listed under UL File E6070. 

 
Underwriters Laboratory recognized (      ) warmers (UL File E6070) - 
Since the warmer is only a single component of a complete installation, 
the finished installation of an         unit requires additional evaluations to              
Underwriters Laboratory standards. 

STD 4 

UL Listed Warmers 

UL Recognized Warmers 

E6070 

 011

  303

308 

  Op

M

anual for 

Built-In

 T

’Stat 

W

a

rmer

WARNING: 

SHOCK HAZARD 

 

All servicing requiring access 
to non-insulated electrical 
components must be        
performed by a factory       
authorized technician. 
DO NOT open any access 
panel which requires the use 
of tools.  Failure to 
follow this warning can 
result in severe electrical 
shock.

 

 

CAUTION: 

RISK OF 
DAMAGE 

 

DO NOT connect or energize 
this appliance until all        
installation instructions are 
read and followed.  Damage 
to the appliance may result if 
these instructions are not 
followed. 

 

 

CAUTION: 

HOT SURFACE 

 

Exposed surfaces can be hot 
to the touch and may cause 
burns. 

This appliance is intended for use in commercial establishments 
only. 

 
This appliance is intended to hold pre-heated food for human       
consumption.  No other use is recommended or authorized by the 
manufacturer or its agents.

 

 

Operators of this appliance must be familiar with the appliance use, 
limitations and associated restrictions.  Operating instructions must be 
read and understood by all persons using or installing this appliance.

 

 

Cleanliness of this appliance is essential to good sanitation.  Read and 
follow all included cleaning instructions and schedules to ensure the 
safety of the food product. 

 

Disconnect this appliance from electrical power before performing any 
maintenance or servicing. 

 

This appliance is not jet stream approved.  Do not direct water jet or 
steam jet at this appliance, or at any control panel or wiring.  Do not 
splash or pour water on, in or over any controls,  control panel or     
wiring.    

 
Exposed surfaces of this appliance can be hot to the touch and may 
cause burns. 

 
Do not operate this appliance if the control panel is damaged.  Call 
your Authorized Wells Service Agent for service.

 

 

The technical content of this manual, including any wiring diagrams, 
schematics, parts breakdown illustrations and/or adjustment 
procedures, is intended for use by qualified technical personnel. 

 

Any procedure which requires the use of tools must be performed by a 
qualified technician. 

 

This manual is considered to be a permanent part of the appliance.  
This manual and all supplied instructions, diagrams, schematics, parts 
breakdown illustrations, notices and labels must remain with the 
appliance if it is sold or moved to another location. 

 

This appliance is made in the USA.  Unless otherwise noted, this 
appliance has American sizes on all hardware.

 

Summary of Contents for BMW-206RTD

Page 1: ...TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELL...

Page 2: ...the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merc...

Page 3: ...l ensure its optimum performance TABLE OF CONTENTS APPLICABILITY INTRODUCTION 1 This manual applies to the following Wells models Half Size Warmers HMP 6 HMP 6D HMP 6ULD HSW 6 HSW 6D Bottom Mount Warm...

Page 4: ...will vary depending upon the type of product and food consistency B MOUNTING 1 Top mounted built in warmers may be equipped with WELLSLOKS uniquely designed turnout tabs which help secure the warmer...

Page 5: ...use is recommended or authorized by the manufacturer or its agents Operators of this appliance must be familiar with the appliance use limitations and associated restrictions Operating instructions mu...

Page 6: ...ies before discarding packing materials Store all accessories in a convenient place for later use INSTALLATION NOTES 1 Installation and start up of built in warmers MUST be performed by an authorized...

Page 7: ...s this appliance must be installed in compliance with Massachusetts Fuel Gas and Plumbing Code CMR 248 1 IMPORTANT All plumbing installations must be performed by a qualified plumber 2 For units equip...

Page 8: ...rmer a Insets are available as accessories in 2 qt 4qt 7 qt and 11 qt sizes with lids and adapter tops b For dry operation a 6 deep pan or inset is recommended 2 Turn temperature control to HI or high...

Page 9: ...e pan with the water level sensor is turned ON 4 Make sure the drain valve is fully closed before turning any thermostats ON 5 The autofill function is only activated when the far left thermostat is t...

Page 10: ...nser residue 4 Inspect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating element causin...

Page 11: ...vers accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control O...

Page 12: ...ot hold water Drain valve not fully closed Check drain valve for debris and close fully Drain valve damaged or pan s leaking Contact your Authorized Wells Service Agency for repairs Auto fill unit ove...

Page 13: ...sher environment Wells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless steel however is mostly iron and will rust pit and cor...

Page 14: ...SMP or 1 side of TMPT to hold one 11 qt and one 7 qt inset 21621 ADAPTER TOP convert 12 x 20 warmer to hold two 7 qt insets 21502 ADAPTER TOP convert 12 x 20 warmer to hold two 4 qt and two 2 qt 21503...

Page 15: ...n Kits for UL Listed units approved for installation in wood counter tops One well units require one kit Two and three well units require two kits four and five well units require three kits DRAIN VAL...

Page 16: ...ION CUSTOMER SATISFACTION Commercial Food Equipment Service Association Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association PRINTED IN UNITED STATES OF AMERICA WELLS...

Reviews: