SERVICING INSTRUCTIONS (continued)
18
REPLACE PRODUCT DELIVERY AUGER
Before attempting major changes, such as installing a different
rate product delivery auger, consult your product supplier for
recommendations as to the required ratio product weight per
volume of water. See the chart below for auger spring delivery
rates.
p/n
PRODUCT DELIVERY
GRAMS
OUNCE OF WATER
S6729
AUGER SPRING
LESS PRODUCT
2.4 to 4.0
S8501
AUGER SPRING
STANDARD DELIVERY
4.1 to 4.6
S3271
AUGER SPRING
MORE PRODUCT
4.7 to 6.3