background image

CLEANING INSTRUCTIONS

PROCEDURE:  Clean Hot Water Dispenser

PRECAUTIONS:    Disconnect dispenser from electric power. 

 

Allow dispenser to cool.

FREQUENCY:    Daily

TOOLS:   

Mild Detergent, Clean Soft Cloth or Sponge

 

Bristle Brush

1.  Disconnect dispenser from electric power. 

 

Allow to cool before cleaning.

2.  Wipe exterior of dispenser with a soft clean cloth or sponge  

moistened with mild detergent and clean water.  Rinse by  

wiping with a soft clean cloth or sponge moistened clean    

water.  

3.  Wipe faucet nozzle to remove any mineral deposits.  A bristle  

brush may be used to remove stubborn mineral build-up.

Procedure is complete

CAUTION:  

BURN HAZARD

Dispensed water is extremely 

hot.  Hot water will cause

serious skin burns.

CAUTION:  

SHOCK HAZARD

Do not submerge or immerse 

dispenser in water.  

IMPORTANT:

DO NOT use steel wool, sharp 

objects, or caustic, abrasive or 

chlorinated cleansers to clean 

the dispenser’s stainless steel 

surfaces.

7

2M-77729-713 OP

 MANUAL, 1223-2G & 1226-5G

2M-77729-713 OP

 MANUAL, 1223-2G & 1226-5G

Summary of Contents for 1223-2G

Page 1: ...ww wellsbloomfield com BLOOMFIELD INDUSTRIES p n 2M 77729 Rev G M713 080805 713 OWNERS MANUAL for HOT WATER DISPENSER FOR EXPORT 2 GALLON MODELS 1223 2G 230V 5 GALLON MODELS 1226 5G 230V Includes Inst...

Page 2: ...anty only decanters excluded THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICU...

Page 3: ...ormation needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1...

Page 4: ...R FLEXIBLE DRAIN LINE WATER SUPPLY CONNECTION TANK HEATER SWITCH POWER LITE READY LITE DISPENSE FAUCET RUBBER GRIP FEET POWER CORD WHEN SUPPLIED THERMOSTAT ACCESS FRONT VIEW REAR VIEW DRAIN LINE TUBIN...

Page 5: ...No other use is recommended or authorized by the manufacturer or its agents This appliance is intended for use in commercial establishments where all operators are familiar with the appliance use limi...

Page 6: ...addle The dispenser must be installed on a water line with average pressure between 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the wat...

Page 7: ...heck valve to be installed on the inlet water line If a backflow preventer is used you must install a water hammer arrester in the incoming line between the backflow preventer and the brewer inlet as...

Page 8: ...er suitable for hot water 2 Hold container under faucet Pull faucet handle to dispense hot water Release handle to stop dispensing A A 1 IMPORTANT Be sure tank is filled with water before pressing tan...

Page 9: ...rgent and clean water Rinse by wiping with a soft clean cloth or sponge moistened clean water 3 Wipe faucet nozzle to remove any mineral deposits A bristle brush may be used to remove stubborn mineral...

Page 10: ...desired temperature Hi Limit safety switch tripped Allow to cool hi limit will self reset Damaged internal component or wiring Examine wiring connectors controller power board and heating element Rep...

Page 11: ...eating elements tubing water level control and plumbing connections Rear panel is held by four screws at the back The flanged top portion fits over the body of the dispenser SOLENOID DOOR Solenoid doo...

Page 12: ...hermobulb Lift out probe jamb nut and gasket Disconnect wiring from thermostat Loosen screws holding thermostat to bracket Remove thermostat Reassemble in reverse order IMPORTANT The thermostat will m...

Page 13: ...enoid Unscrew inlet fitting cap to release solenoid from door Remove wiring from solenoid Transfer fill tube from old solenoid to new solenoid Reassemble in reverse order REPAIR HOT WATER FAUCET Unplu...

Page 14: ...shut off valve and disconnect the water supply line from the inlet fitting Remove the tank lid assembly as detailed on page 10 Using the drain tube drain all water from water tank When finished be su...

Page 15: ...120V 1222 1222CA 2E 75760 Solenoid Complete Single 240V 1225 1226 WS 85218 Inlet Fitting Kit includes cap fitting washer screen WS 85219 Inlet Strainer only 2M 77729 713 OP MANUAL 1223 2G 1226 5G CAP...

Page 16: ...G shown Model 1226 5G is similar IL1856 Rev A 8 05 09 Model 1223 2G 230V 1226 5G 230V 38 39 37 1 34 27 2 REQD 36 28 35 31 29 40 18 26 24 22 21 21 20 2 REQD 19 17 16 15 14 13 12 11 10 9 7 8 6 5 4 3 30...

Page 17: ...9 TUBE 3 8 x 3 4 LONG 2A 75609 20 TUBE SILICONE 312 DI x 25 LONG A6 73540 21 TUBE BRAIDED 312 ID x 21 LONG A6 76237 22 CLAMP HOSE SHUT OFF 2C 76564 23 GASKET HEATING ELEMENT 2I 70152 24 GASKET TANK 25...

Page 18: ...INPUT WHITE GREEN WATER LEVEL PROBE 4 11 7 7 9 10 12 13 6 8 3 2 5 1 BLUE BROWN GREEN YELLOW WHITE WHITE WHITE WHITE WHITE BLACK BLACK BLACK BLACK BLACK BLACK BLACK HOT WATER READY LIGHT AMBER POWER L...

Page 19: ...E WHITE RED 12 ga RED 12 ga WHITE GREEN WHITE BLACK 12 ga BLACK BLACK 12 ga BLACK BLACK BLACK BLACK BLACK BLACK HOT WATER READY LIGHT AMBER POWER LIGHT GREEN THERMOSTAT WATER LEVEL PROBE TANK HEATER S...

Page 20: ...10 Sunnen Drive St Louis MO 63143 telephone 800 807 9054 fax 314 781 2714 www wellsbloomfield com...

Reviews: