CAUTION: 

CHEMICAL BURN 
HAZARD

Deliming chemicals may be 

caustic.  Wear appropriate 

protective gloves and goggles 

during this procedure.  Never 

siphon deliming chemicals or 

solutions by mouth.

This operation should only be 

performed by qualified and    

experienced service personnel.

IMPORTANT: 

 DO NOT spill, 

splash or pour water or deliming 

solution into or over any internal 

component other than the inside 

of the water tank.

IMPORTANT: 

 DO NOT allow 

any internal components to 

come into contact with the     

deliming solution.  Take care to 

keep all internal components 

dry.

NOTE:

  Repeat steps 4 thru 5 

as required to remove all scale 

and lime build-up.

NOTE: 

 Normally, silicone 

hoses do not need to be 

delimed.  Should deliming hoses 

become necessary, Bloomfield 

recommends replacing the 

hoses

PROCEDURE:  Delime the Water Tank 

PRECAUTIONS:    Disconnect dispenser from electric power. 

 

Allow dispenser to cool.

FREQUENCY:    As required (dispenser slow to heat)

TOOLS:   

Deliming Solution

 

Protective Gloves, Goggles & Apron

 

Mild Detergent, Clean Soft Cloth or Sponge

 

Bristle Brush, Bottle Brush

 

Large Sink (or other appropriate work area)

Unplug power cord.  Turn off the water shut-off valve and  

disconnect the water supply line from the inlet fitting.

Remove the tank lid assembly as detailed on page 10.
Using the drain tube, drain all water from water tank.  When 

finished, be sure drain tube clamp is secured.

Mix 2 gallons of deliming solution according to the             

manufacturer’s directions.  Carefully pour the deliming  

solution into the water tank.  Lower the lid assembly back    

onto the tank.  Allow to sit for 30 minutes, or as directed by  

the  manufacturer.
At end of soaking period, remove lid assembly from tank.   

Thoroughly rinse internal components of lid assembly with  

clear water.  Using a stiff bristle brush, scrub the heating     

element to remove lime and calcium build-up.  Rinse with  

clean water. Store lid assembly in a safe location.
Drain the water tank.  Using a stiff bristle brush, scrub the   

interior of the water  tank to remove lime and calcium build- 

up.  Rinse with clean water.
Reassemble the tank lid to the water tank.  Make sure the  

gasket is properly in place.  Reinstall wiring to heating        

element and thermostat.  Reinstall fill and vent  tubes.  

Reconnect water supply.  Plug in power cord.

Allow dispenser to fill, then drain.  Repeat three times.

Press tank heater switch “ON”.  When ready light glows,  

dispenser is ready to use.

1.

2.
3.

4.

5.

6.

7.

8.
9.
10.

SERVICING INSTRUCTIONS (continued)

12

2M-77729-713 OP

 MANUAL, 1223-2G & 1226-5G

2M-77729-713 OP

 MANUAL, 1223-2G & 1226-5G

Summary of Contents for 1223-2G

Page 1: ...ww wellsbloomfield com BLOOMFIELD INDUSTRIES p n 2M 77729 Rev G M713 080805 713 OWNERS MANUAL for HOT WATER DISPENSER FOR EXPORT 2 GALLON MODELS 1223 2G 230V 5 GALLON MODELS 1226 5G 230V Includes Inst...

Page 2: ...anty only decanters excluded THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICU...

Page 3: ...ormation needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1...

Page 4: ...R FLEXIBLE DRAIN LINE WATER SUPPLY CONNECTION TANK HEATER SWITCH POWER LITE READY LITE DISPENSE FAUCET RUBBER GRIP FEET POWER CORD WHEN SUPPLIED THERMOSTAT ACCESS FRONT VIEW REAR VIEW DRAIN LINE TUBIN...

Page 5: ...No other use is recommended or authorized by the manufacturer or its agents This appliance is intended for use in commercial establishments where all operators are familiar with the appliance use limi...

Page 6: ...addle The dispenser must be installed on a water line with average pressure between 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the wat...

Page 7: ...heck valve to be installed on the inlet water line If a backflow preventer is used you must install a water hammer arrester in the incoming line between the backflow preventer and the brewer inlet as...

Page 8: ...er suitable for hot water 2 Hold container under faucet Pull faucet handle to dispense hot water Release handle to stop dispensing A A 1 IMPORTANT Be sure tank is filled with water before pressing tan...

Page 9: ...rgent and clean water Rinse by wiping with a soft clean cloth or sponge moistened clean water 3 Wipe faucet nozzle to remove any mineral deposits A bristle brush may be used to remove stubborn mineral...

Page 10: ...desired temperature Hi Limit safety switch tripped Allow to cool hi limit will self reset Damaged internal component or wiring Examine wiring connectors controller power board and heating element Rep...

Page 11: ...eating elements tubing water level control and plumbing connections Rear panel is held by four screws at the back The flanged top portion fits over the body of the dispenser SOLENOID DOOR Solenoid doo...

Page 12: ...hermobulb Lift out probe jamb nut and gasket Disconnect wiring from thermostat Loosen screws holding thermostat to bracket Remove thermostat Reassemble in reverse order IMPORTANT The thermostat will m...

Page 13: ...enoid Unscrew inlet fitting cap to release solenoid from door Remove wiring from solenoid Transfer fill tube from old solenoid to new solenoid Reassemble in reverse order REPAIR HOT WATER FAUCET Unplu...

Page 14: ...shut off valve and disconnect the water supply line from the inlet fitting Remove the tank lid assembly as detailed on page 10 Using the drain tube drain all water from water tank When finished be su...

Page 15: ...120V 1222 1222CA 2E 75760 Solenoid Complete Single 240V 1225 1226 WS 85218 Inlet Fitting Kit includes cap fitting washer screen WS 85219 Inlet Strainer only 2M 77729 713 OP MANUAL 1223 2G 1226 5G CAP...

Page 16: ...G shown Model 1226 5G is similar IL1856 Rev A 8 05 09 Model 1223 2G 230V 1226 5G 230V 38 39 37 1 34 27 2 REQD 36 28 35 31 29 40 18 26 24 22 21 21 20 2 REQD 19 17 16 15 14 13 12 11 10 9 7 8 6 5 4 3 30...

Page 17: ...9 TUBE 3 8 x 3 4 LONG 2A 75609 20 TUBE SILICONE 312 DI x 25 LONG A6 73540 21 TUBE BRAIDED 312 ID x 21 LONG A6 76237 22 CLAMP HOSE SHUT OFF 2C 76564 23 GASKET HEATING ELEMENT 2I 70152 24 GASKET TANK 25...

Page 18: ...INPUT WHITE GREEN WATER LEVEL PROBE 4 11 7 7 9 10 12 13 6 8 3 2 5 1 BLUE BROWN GREEN YELLOW WHITE WHITE WHITE WHITE WHITE BLACK BLACK BLACK BLACK BLACK BLACK BLACK HOT WATER READY LIGHT AMBER POWER L...

Page 19: ...E WHITE RED 12 ga RED 12 ga WHITE GREEN WHITE BLACK 12 ga BLACK BLACK 12 ga BLACK BLACK BLACK BLACK BLACK BLACK HOT WATER READY LIGHT AMBER POWER LIGHT GREEN THERMOSTAT WATER LEVEL PROBE TANK HEATER S...

Page 20: ...10 Sunnen Drive St Louis MO 63143 telephone 800 807 9054 fax 314 781 2714 www wellsbloomfield com...

Reviews: