Safety Instructions - continued

å  

Follow all installation, operating, and use instructions.

å  

Unplug the unit from the AC power outlet before cleaning. Use only a damp cloth for cleaning the exterior of the unit.

å  

Do not use accessories or attachments not recommended by Blonder Tongue, as they may cause hazards, and will void the warranty.

å  

Do not operate the unit in high-humidity areas, or expose it to water or moisture.

å  

Do not place the unit on an unstable cart, stand, tripod, bracket, or table. The unit may fall, causing serious personal injury and damage to the 

unit.

å  

Do not block or cover slots and openings in the unit. These are provided for ventilation and protection from overheating.  Never place the unit 

near or over a radiator or heat register. Do not place the unit in an enclosure such as a cabinet without proper ventilation. Do not mount equip-

ment in the rack space directly above or below the unit.

å  

Operate the unit using only the type of power source indicated on the marking label. Unplug the unit power cord by gripping the plug, not the cord.

å  

The unit is equipped with a three-wire ground-type plug. This plug will fit only into a ground-type power outlet. If you are unable to insert the 

plug into the outlet, contact an electrician to replace the outlet. Do not defeat the safety purpose of the ground-type plug.

å  

Route power supply cords so that they are not likely to be walked on or pinched by items placed upon or against them. Pay particular attention 

to cords at plugs, convenience receptacles, and the point where they exit from the unit.

å  

Be sure that the outdoor components of the antenna system are grounded in accordance with local, federal, and National Electrical Code (NEC) 

requirements. Pay special attention to NEC Sections 810 and 820.  See the example shown in the following diagram:

å  

We strongly recommend using an outlet that contains surge suppression or ground fault protection. For added protection during a lightning 

storm, or when the unit is left unattended and unused for long periods of time, unplug it from the wall outlet and disconnect the lines between 

the unit and the antenna. This will prevent damage caused by lightning or power line surges.

å  

 Do not locate the antenna near overhead power lines or other electric light or power circuits, or where it can fall into such power lines or circuits. 

When installing the antenna, take extreme care to avoid touching such power lines or circuits, as contact with them can be fatal.

å  

Do not overload wall outlets or extension cords, as this can result in a risk of fire or electrical shock.

å  

 Never insert objects of any kind into the unit through openings, as the objects may touch dangerous voltage points or short out parts. This could 

cause fire or electrical shock.

å  

 Do not attempt to service the unit yourself, as opening or removing covers may expose you to dangerous voltage and will void the warranty. Refer 

all servicing to authorized service personnel.

å  

 Unplug the unit from the wall outlet and refer servicing to authorized service personnel whenever the following occurs:

 

 The power supply cord or plug is damaged;

 

o

  Liquid has been spilled, or objects have fallen into the unit;

 

o

  The unit has been exposed to rain or water;

 

o

  The unit has been dropped or the chassis has been damaged;

 

o

 The unit exhibits a distinct change in performance.

å  

 When replacement parts are required, ensure that the service technician uses replacement parts specified by Blonder Tongue. Unauthorized 

substitutions may damage the unit or cause electrical shock or fire, and will void the warranty.

å  

 Upon completion of any service or repair to the unit, ask the service technician to perform safety checks to ensure that the unit is in proper 

operating condition.

Returning Product for Repair (or Credit)
A Return Material Authorization (RMA) Number is required on all products returned to Blonder Tongue

regardless if 

the product is being returned for repair or credit. 

Before returning product, please contact the Blonder Tongue Service 

Department at 1-800-523-6049, Ext. 4256 or visit our website: 

www.blondertongue.com 

for further information.

Summary of Contents for 5800 13

Page 1: ...nt No Issue No Author ACTIVE 9 08 2014 651187000 P 1 KK Stock No 5800 USER MANUAL Stock No 5800 USER MANUAL Model Stock No Model Stock No BIDA 55A 30 5800 53 BIDA 86A 30 5800 83 BIDA 55A 30P 5800P53 BIDA 86A 30P 5800P83 BIDA 55A 43 5800 54 BIDA 86A 43 5800 84 BIDA 55A 43P 5800P54 BIDA 86A 43P 5800P84 BIDA 55A 50 5800 55 BIDA 100A 30 5800 13 BIDA 75A 30 5800 73 BIDA 100A 30P 5800P13 BIDA 75A 30P 58...

Page 2: ...econfigured by using plug in fixed attenuators forward and return and cable slope equalizers forward to meet particu lar requirements Push pull and power doubling hybrid modules hybrid IC modules enable the BIDA ARP to operate at high output levels while retaining low distortion characteristics The aluminum chassis is designed to provide excellent heat dissipation thus allowing operation at high a...

Page 3: ...tions before you operate the unit å Retain all safety and operating instructions for future reference å Heed all warnings on the unit and in the safety and operating instructions WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE NOTE TO CATV SYSTEM INSTALLER This reminder is provided to call the CATV System Installer s attention to Article 820 40 of the NEC that p...

Page 4: ...ring a lightning storm or when the unit is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the lines between the unit and the antenna This will prevent damage caused by lightning or power line surges å Do not locate the antenna near overhead power lines or other electric light or power circuits or where it can fall into such power lines or circuits...

Page 5: ...NTROL CIRCUIT 49 MHz HPF2 36 MHz LPF2 ATT INPUT OUTPUT 30 dB TEST 49 MHz HPF1 36 MHz LPF1 ATT GAIN CONTROL FULL GAIN CONTROL RETURN AMPLIFIER J11 24V J13 P3 P1 FLAT ATTENUATOR PASSIVE PASSIVE ACTIVE ACTIVE P2 ON OFF J12 PASSIVE RETURN PATH NOTE Passive Return Path Short Plug P1 on J11 and P3 on J13 to passive and P2 on J12 to off Active Return Path Short Plug P1 on J11 and P3 on J13 to active and ...

Page 6: ... Channels for CSO CTB XMD 77 110 129 150 3 Output Level 36 44 dBmV 36 44 dBmV 36 44 dBmV 32 40 dBmV 42 Composite Triple Beat CTB 64 dB 71 dB 63 dB 68 dB 63 dB 60 dB 64 dB 56 dB 64 dB 54 dB 62 dB 56 dB 60 dB 59 dB 70 dB 65 dB 70 dB 60 Crossmodulation XMOD 67 dB 74 dB 66 dB 69 dB 60 dB 62 dB 68 dB 60 dB 68 dB 54 dB 62 dB 60 dB 65 dB 60 dB 66 dB 58 dB 66 dB 60 2nd Order Composite CSO 61 dB 65 dB 60 d...

Page 7: ...ock wise After in sert ing Cable Equalizer rotate Cable Equalizer clamp counter clockwise so it lays atop the mount ing tab Tighten mounting screw to secure Ca ble Equalizer clamp po si tion View A Specify dB value BIDA FA Flat Attenuator Stock No 5411A Plug in flat attenuator pad for reducing forward and or return gain in BIDA series amplifiers The BIDA FA is avail able in fixed values of 1 20 dB...

Page 8: ...8 BIDA Series Instruction Manual NOTES ...

Page 9: ...9 BIDA Series Instruction Manual NOTES ...

Page 10: ...10 BIDA Series Instruction Manual NOTES ...

Page 11: ...y any person other than Blonder Tongue Service Department 9 Any modification of the product by any person other than Blonder Tongue Service Department 10 Fire flood war civil disturbance industrial action acts of God or any other causes beyond the reasonable control of Blonder Tongue 11 Any defect caused by lightning strike or power surges 12 Shipping costs to return products to Blonder Tongue for...

Page 12: ...TAL PUNITIVE DIRECT OR SPECIAL DAMAGES BASED UPON BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT TORT LIABILITY OR OTHERWISE OR ANY OTHER LEGAL THEORY ARISING DIRECTLY OR INDIRECTLY FROM THE SALE USE INSTALLATION OR FAILURE OF ANY PRODUCT ACQUIRED BY BUYER FROM BT All claims for shortages defects and non conforming goods must be made by the customer in writing within five 5 days of receip...

Reviews: