BIDA Series

Instruction Manual 

Safety Instructions

å  

Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment 

may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the 

maximum ambient temperature.

å  

Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment 

is not compromised.

å  

Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

å  

Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of 

the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used 

when addressing this concern.

å 

  

Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connec-

tions other than direct connections to the branch circuit (e.g. use of power strips).

å  

Read all safety and operating instructions before you operate the unit.

å  

Retain all safety and operating instructions for future reference.

å  

Heed all warnings on the unit and in the safety and operating instructions.

WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE

NOTE TO CATV SYSTEM INSTALLER

This reminder is provided to call the CATV System Installer’s attention to Article 820-40 of the NEC that provides guidelines for 

proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as 

close to the point of cable entry as practical.

The STOP sign symbol is intended to alert you to the presence of REQUIRED operating and maintenance 
(servicing) instructions that if not followed, may result in product failure or destruction.

TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER FROM THIS UNIT.   

NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

Section 1 — General & Safety Instructions

The YIELD sign symbol is intended to alert you to the presence of RECOMMENDED operating and maintenance 
(servicing) instructions.

The LIGHTNING flash symbol is intended to alert you to the presence of uninsulated "dangerous voltage" 
within the product's enclosure that may be of sufficient magnitude to constitute a risk of electrical shock.

YOU SHOULD ALWAYS FOLLOW THESE INSTRUCTIONS TO HELP ENSURE

AGAINST INJURY TO YOURSELF AND DAMAGE TO YOUR EQUIPMENT.

Summary of Contents for 5800 13

Page 1: ...nt No Issue No Author ACTIVE 9 08 2014 651187000 P 1 KK Stock No 5800 USER MANUAL Stock No 5800 USER MANUAL Model Stock No Model Stock No BIDA 55A 30 5800 53 BIDA 86A 30 5800 83 BIDA 55A 30P 5800P53 BIDA 86A 30P 5800P83 BIDA 55A 43 5800 54 BIDA 86A 43 5800 84 BIDA 55A 43P 5800P54 BIDA 86A 43P 5800P84 BIDA 55A 50 5800 55 BIDA 100A 30 5800 13 BIDA 75A 30 5800 73 BIDA 100A 30P 5800P13 BIDA 75A 30P 58...

Page 2: ...econfigured by using plug in fixed attenuators forward and return and cable slope equalizers forward to meet particu lar requirements Push pull and power doubling hybrid modules hybrid IC modules enable the BIDA ARP to operate at high output levels while retaining low distortion characteristics The aluminum chassis is designed to provide excellent heat dissipation thus allowing operation at high a...

Page 3: ...tions before you operate the unit å Retain all safety and operating instructions for future reference å Heed all warnings on the unit and in the safety and operating instructions WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE NOTE TO CATV SYSTEM INSTALLER This reminder is provided to call the CATV System Installer s attention to Article 820 40 of the NEC that p...

Page 4: ...ring a lightning storm or when the unit is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the lines between the unit and the antenna This will prevent damage caused by lightning or power line surges å Do not locate the antenna near overhead power lines or other electric light or power circuits or where it can fall into such power lines or circuits...

Page 5: ...NTROL CIRCUIT 49 MHz HPF2 36 MHz LPF2 ATT INPUT OUTPUT 30 dB TEST 49 MHz HPF1 36 MHz LPF1 ATT GAIN CONTROL FULL GAIN CONTROL RETURN AMPLIFIER J11 24V J13 P3 P1 FLAT ATTENUATOR PASSIVE PASSIVE ACTIVE ACTIVE P2 ON OFF J12 PASSIVE RETURN PATH NOTE Passive Return Path Short Plug P1 on J11 and P3 on J13 to passive and P2 on J12 to off Active Return Path Short Plug P1 on J11 and P3 on J13 to active and ...

Page 6: ... Channels for CSO CTB XMD 77 110 129 150 3 Output Level 36 44 dBmV 36 44 dBmV 36 44 dBmV 32 40 dBmV 42 Composite Triple Beat CTB 64 dB 71 dB 63 dB 68 dB 63 dB 60 dB 64 dB 56 dB 64 dB 54 dB 62 dB 56 dB 60 dB 59 dB 70 dB 65 dB 70 dB 60 Crossmodulation XMOD 67 dB 74 dB 66 dB 69 dB 60 dB 62 dB 68 dB 60 dB 68 dB 54 dB 62 dB 60 dB 65 dB 60 dB 66 dB 58 dB 66 dB 60 2nd Order Composite CSO 61 dB 65 dB 60 d...

Page 7: ...ock wise After in sert ing Cable Equalizer rotate Cable Equalizer clamp counter clockwise so it lays atop the mount ing tab Tighten mounting screw to secure Ca ble Equalizer clamp po si tion View A Specify dB value BIDA FA Flat Attenuator Stock No 5411A Plug in flat attenuator pad for reducing forward and or return gain in BIDA series amplifiers The BIDA FA is avail able in fixed values of 1 20 dB...

Page 8: ...8 BIDA Series Instruction Manual NOTES ...

Page 9: ...9 BIDA Series Instruction Manual NOTES ...

Page 10: ...10 BIDA Series Instruction Manual NOTES ...

Page 11: ...y any person other than Blonder Tongue Service Department 9 Any modification of the product by any person other than Blonder Tongue Service Department 10 Fire flood war civil disturbance industrial action acts of God or any other causes beyond the reasonable control of Blonder Tongue 11 Any defect caused by lightning strike or power surges 12 Shipping costs to return products to Blonder Tongue for...

Page 12: ...TAL PUNITIVE DIRECT OR SPECIAL DAMAGES BASED UPON BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT TORT LIABILITY OR OTHERWISE OR ANY OTHER LEGAL THEORY ARISING DIRECTLY OR INDIRECTLY FROM THE SALE USE INSTALLATION OR FAILURE OF ANY PRODUCT ACQUIRED BY BUYER FROM BT All claims for shortages defects and non conforming goods must be made by the customer in writing within five 5 days of receip...

Reviews: