In case of fire:
- suitable extinguishing devices are alcohol-based foam or carbon dioxide
- Please have an extinguisher readily available.
Maintenance / Care instructions:
- Please let the fireplace cool down for at least 15 minutes before starting the cleaning process.
- The burner must be cleaned regularly. It is recommended to clean it after 100 hours of service. Use
warm water and washing-up liquid.
- Marks can be best removed with a soft cloth and a mixture of lukewarm water and a small amount
of cleaning liquid (ph-neutral). We recommend to clean the stainless steel item regularly to prevent
contamination.
- To seal the surface we recommend our blomus stainless steel maintenance spray. This creates a
dirt-deflecting protective film and works preventing against scaling.
- CAUTION! Never use chemicals like white spirits, turpentine or fuel. Do not use Steel-wool or sc-
rubbing sponges either. The surface can be scratched by these. The manufacturer can not be held
responsible for any damages resulting out of false use and / or cleaning of the product.
Technical Data:
TÜV-testing:
Tests of the fireplaces 65169 and 65170 performed at TÜV Süd Industrie Service (Munich, Germany)
resulted in the following:
- The carbon monoxide (CO) content in the room air is not exceeding the limit value of 30 ppm given in the
regulations (BayFeuV) in dependence of a minimum room volume and minimum room ventilation as speci-
fied in the below chart.
- The maximum fuel mass flow of 0.5l / h (16.9 fl oz / h) was not exceeded.
- The maximum outer wall temperature of 85° C / 185 F for adjacent devices with flammable materials
was, provided that installation has been done according to the manual, not exceeded.
- The carbon dioxide (CO2) content in the room air is not exceeding a maximum of 5000 ppm in the de-
pendence of the minimum room volume and minimum room ventilation as specified in the below chart.
65169
65170
Height
83,5 cm / 32.87 inch
130 cm / 51.18 inch
Width
30 cm / 11.81 inch
30,3 cm / 11.93 inch
Depth
30 cm / 11.81 inch
17,8 cm / 7.01 inch
Weight
19,7 kg / 43.43 lbs
15,6 kg / 34.39 lbs
Burner capacity
0,72 L / 24.35 fl oz
0,72 L / 24.35 fl oz
Fuel
blomus Bio-Alcohol, art.-no. 31034 (denatured alcohol, consisting of app 96% ethanol,
1% MEK, 4-6% water, Bitrex 100g/1000L 3.52 oz / 264 gal)
Min. Room volume (m³
/ cuf)
Air change (1/h)
Comments
280 / 9888
0,2
Air change rate with windows closed
95 / 3355
0,6
With standard ventilation / slightly open windows
56 / 1978
1,0
Complete change of air within 1 hour / open windows
- The following chart shows estimates air change rates according to
1)
:
1)
Recknagel, Sprenger, Schrameck: H Klimatechnik
Air change (1/h)
Comments
0 - 0,5
Windows, doors closed
0,3 - 1,5
Windows uncovered, slightly open
5 - 10
Windows halfway open