- Please read these instructions carefully before the first use of the fireplace and keep the safety
instructions for future reference.
- To operate the fireplace we recommend only the use of blomus bio-ethanol (item code 31034).
- Please check the content of the box.
- ATTENTION: Please check with your insurance company and landlord or local authorities for details
and regulations before using the fireplace.
Included in delivery (see illustration 1-3):
- Fireplace body (A)
- Burner reservoir (B) with sliding cover and safety compartment
- Grill (C)
- Mounting bar unit (D) (# 65170 only)
- 2 screws (6 x 60) (E) (# 65170 only)
- 2 washers (F) (# 65170 only)
- 2 wall plugs (S8) (G) (# 65170 only)
- Controller Tool (H)
- Funnel (I)
- Measuring jug (J)
- Liquid fuel (K) (blomus 31034 Bio-Alcohol (ethanol), 1 Litre / 33,8 fl oz) *
- Instruction manual and safety instructions
* NOT included in USA and Canada
Safety instructions:
- WARNING:
- Risk of Explosion:
- Never use any fuel other than the fuels specifically identified for use in the heater. Never use gaso-
line.
- Never refill heater fuel reservoir when heater is operating or still hot.
- Never use heater in areas where flammable vapors or gas may be present.
- Never store or transport the fuel in other than a metal or plastic container that is:
- Acceptable for use with the specific fuel,
- Non red in color,
- Is in the original container for the (specific alcohol) Fuel.
- Never store fuel in the living space.
- Due to high surface temperatures, keep children, clothing, and furniture away.
- Risk of Indoor Air Pollution - Use heater only in well-ventilated areas. People with breathing problems
should consult a physician before using the heater.
- Do not use heater to heat or boil water or use as a cooking appliance.
- WARNING: This appliance has not been tested with an unvented gas log set. To reduce risk of fire or
injury, do not install an unvented gas log set into this appliance.
- Always keep the room where the fireplace is operated ventilated. While burning the fire uses oxygen out
of the air.
- Never blow air into the flame! Blowing air into the flame can lead to severe injuries from darting flames.
- Please avoid movements within the scope of the flame (see illustration 11)
- When ventilated, the minimum room size per opreated fireplace 65169 and / or 65170 must not be
less than 56m³ / 1978 cuf (equalling 25,5 m² / 274.5 sqf room size with a ceiling of 2,20 m / 7,2
ft).
- When burning bio-ethanol water-vapour and carbon dioxide are produced.
- Never use the burner without the safety compartment.
- It is not recommended to use more than one fireplace at a time in one room.
Fireplace CHIMO, Instruction Manual / Safety Instructions