background image

 

 

 

 

 

EN 

7

 

Mounting the hood body 

• Before attaching the hood body, tighten the two 

screws 

Vr

 located on the hood body mounting points. 

•  Hook the hood body onto the screws 

12a

•  Fully tighten the support screws 

12a

•  Adjust the screws 

Vr

 to level the hood body. 

 

12a

Vr

Connections 

DUCTED VERSION AIR EXHAUST SYSTEM 

When installing the ducted version, connect the hood to 

the chimney using either a flexible or rigid pipe ø 150 
or 120 mm, the choice of which is left to the installer. 
•  To install a ø 120 mm air exhaust connection, insert 

the reducer flange 

9

 on the hood body outlet. 

•  Fix the pipe in position using sufficient pipe clamps 

(not supplied). 

•  Remove possible charcoal filters. 

 

9

ø 120

ø 150

RECIRCULATION VERSION AIR OUTLET 

•  Push fit connection 

15

 onto the hood body outlet

.

 

•  Insert the connection extension pieces laterally 

14.1

 

in connection 

15.

 

•  Make sure that the outlet of the extension pieces 

14.1

 

is horizontally and vertically aligned with the chim-
ney outlets. If this is not the case, adjust the position 
by either reversing the connection extension pieces 

14.1

 and then reassemble as described previously. 

•  Ensure that the activated charcoal filters have been 

inserted. 

 

14.1

15

Summary of Contents for DKP 5160

Page 1: ......

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 4 CHARACTERISTICS 5 INSTALLATION 6 USE 9 MAINTENANCE 11 EN ...

Page 3: ...llationforthegashobspecifyagreaterdistancespecifiedabove thishas tobetakenintoaccount Regulationsconcerningthedischargeofairhavetobefulfilled USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom...

Page 4: ... 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange ø 150 120 mm 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual 2 1 2 2 2 12c 12a 7 2 1 11 11 12a 1 14 1 15 9 ...

Page 5: ...all as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 320 mm above the horizontal reference line Repeat this operation on the other side Drill ø 8 mm holes at all the centre...

Page 6: ... 120 mm air exhaust connection insert the reducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not supplied Remove possible charcoal filters 9 ø120 ø150 RECIRCULATION VERSION AIR OUTLET Push fit connection 15 onto the hood body outlet Insert the connection extension pieces laterally 14 1 in connection 15 Make sure that the outlet of the extension pieces 14...

Page 7: ...assembly Upper exhaust Chimney Slightly widen the two sides of the upper chimney and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 supplied Lower exhaust Chimney Slightly widen the two sides of the chimney and hook them between the upper chimney and the wall making sure that they are well seated Fix the l...

Page 8: ...is switched off T2 Speed on Second speed T3 Speed on Third speed T4 Speed Fixed Max speed Flashing Intensive speed Suitable for the strongest cooking vapours and odours The func tion becomes active when the button is pushed for about 2 sec onds After 10 minutes of functioning it turns off automatically This function can be interrupted by means of pressing any of the buttons ...

Page 9: ...on and off at low speed Used to provide a continuous and silent air change in the presence of light cooking vapours V2 Speed Medium speed suitable for most operating conditions given the optimum treated air flow noise level ratio V3 Speed Maximum speed used for eliminating the highest cooking vapour emission including long periods ...

Page 10: ... handle is visi ble on the outside Activatedcharcoalfilter Recirculationversion REPLACINGTHEACTIVATEDCHARCOALFILTER The filter is not washable and cannot be regenerated and must be replaced approximately every 4 months of opera tion or more frequently for particularly heavy usage Remove the metal grease filters Remove the saturated activated carbon filter by releasing the fixing hooks Fit the new ...

Page 11: ...0845 6046859 0345 6046859 0845 6046859 0345 6046859 0845 6046859 0345 6046859 0845 6046859 0345 6046859 0845 6046859 0345 6046859 How to obtain to service ...

Page 12: ...Guarantee details ...

Page 13: ...436002680_ver10 www blomberginternational com ...

Reviews: