OP
ER
AT
ION
19
Problem:
Cause:
Solution:
Spinner does not clamp or
clamps slowly on drill pipe
(or unclamp).
Lack of air pressure. Air supply should be 100-125 psi @240
CFM.
Air hose, both supply and cylinder hoses
are free, not pinched and without leaks.
Check all connections for leaks or
restrictions.
Check Filter, clean and drain as required.
Check lubricator level
(SAE 10 non-detergent oil).
Fault door valve.
Remove valve and install valve repair kit
or replace valve.
Air leaking across
cylinder piston.
Remove and install cylinder repair kit.
Door valve exhaust
blocked.
Check for obstruction blocking the door
valve exhaust port. Remove and clean.
Air motor does not
operate or
operates slowly.
Lack of air pressure. See above solutions under
“Lack of Air Pressure”
Check quick disconnects at air
motor for both supply and
exhaust.
Exhaust mufflers
clogged.
Remove and clean or replace.
Troubleshooting
Summary of Contents for 9G-3570AIR
Page 1: ...1 Blohm Voss Oil Tools LLC GRAYCHAIN 3570 PNEUMATIC 9G 3570AIR Technical Documentation...
Page 6: ...INTRODUCTION 6 INTRODUCTION...
Page 9: ...SPECIFICATIONS 9 SPECIFICATIONS...
Page 12: ...INSTALLATION 12 INSTALLATION...
Page 15: ...OPERATION 15 OPERATION...
Page 18: ...OPERATION 18 Figure 6...
Page 21: ...MAINTENANCE INSPECTION 20 MAINTENANCE...
Page 26: ...MAINTENANCE INSPECTION 25 Lubrication Points Figure 10...
Page 27: ...ASSEMBLIES 26 ASSEMBLIES...
Page 29: ...ASSEMBLIES 28 CASE ASSEMBLY 9G 1022ASSM Figure 12...
Page 31: ...ASSEMBLIES 30 MOTOR MOUNT SUB ASSEMBLY 9G1084 2 Figure 14...
Page 33: ...ASSEMBLIES 32 AIR MOTOR AND REDUCER ASSEMBLY 9G1001 4 Figure 15...
Page 40: ...ASSEMBLIES 39 RIGHT DOOR ASSEMBLY 9G 13035 1 Figure 21...
Page 42: ...ASSEMBLIES 41 LEFT DOOR ASSEMBLY 9G 13035 2 Figure 22...
Page 57: ...SPARE PARTS 56 SPARE PARTS...
Page 59: ...INDEX 58 INDEX...
Page 70: ...INDEX 69 X Y Z ZERK 36 43...