background image

11

6.0  TROUBLESHOOTING MAINTENANCE

6.1  PREVENTIVE MAINTENANCE

No preventive maintenance is required other than adhering to the Cleaning Procedure
instructions.

6.2  DRAW-OFF VALVE LEAKS

If a leak occurs through the valve steam, replace the “O” ring.  If the leak can be attributed to
faulty sealing occurring between the stem disc and valve seat, then quite often this problem can
be corrected by cleaning off the dried on food residue with an extremely fine emery cloth or the
rubber vulcanized stem piece has been damaged and must be replaced.

6.3 EXTREMELY SLOW COOKING TIME

If the cooking time is abnormally slow then the difficulty may be due to insufficient steam
pressure and/or volume.  First determine that pressure on incoming steam line at kettle is within
5 p.s.i. of rated kettle pressure.  Note that pressures approaching the rated kettle pressure are
liable to set off the safety relief valve.  If required pressure is available to kettle, then possibly
volume of steam is not sufficient.  Minimum 3/4" pipe size is required to the kettle but if the steam
generating source is at a great distance from the kettle, larger pipe will be required.  Finally, the
core of the steam supply pipe may have debris or scalants that impede steam flow and will
require disassembly and inspection.

6.4   AIR VENTING

It is recommended that the “optional” steam trap assembly be installed.  This should be plumbed
to the exit end of the kettle.  The thermostatic trap is a mechanical device that closes on high
temperature and opens when the temperature drops, allowing the water which formed from
condensate to exhaust but retain the steam under pressure.

The temperatures required for the cooking process to function adequately must be greater than
the boiling point of the liquid food product, that is, water.  The greater the steam pressure used,
the higher the temperature and the quicker the cooking process.  For example, steam
pressurized at 30 p.s.i. reaches a temperature of 274 degrees Fahrenheit (135 degrees Celsius).
Since air is an unsuitable media through which heat may be transferred, the air should be
exhausted from the jacket by opening the pressure relief valve until the air has been completely
replaced by pressurized steam.

In the initial stages of the cooking process when the steam comes in contact with the cold kettle
bowl surface, it condenses and forms a large amount of water. The condensate water must be
removed from the kettle jacket in order for the kettle to function adequately. The ball valve
located at the base of the kettle jacket may be opened to remove the water. It may be necessary
to repeat this procedure several times depending on the number of batches being cooked as
each batch will create condensate. If the kettle appears to be slow in heating, this would indicate

NOTICE:  Draw-off valve has a vulcanized rubber coated stem for better sealing.  Do not over
tighten.  This may cause the rubber to pull away from stem and permanently damage it.

Summary of Contents for KLT-100DS

Page 1: ...TILTING KETTLE AND DIRECT STEAM PEDESTAL TILTING KETTLE INSTALLATION OPERATION MAINTENANCE BLODGETT OVEN COMPANY www blodgett com 44 Lakeside Avenue Burlington Vermont 05401 USA Telephone 800 331 5842...

Page 2: ...possible injury or death WARNING Improper installation operation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance...

Page 3: ...SERVICE CONNECTIONS KLT DS 4 INSTALLATION AND SERVICE CONNECTIONS KPT DS 5 1 0 INSTALLATION INSTRUCTIONS 6 2 0 INTRODUCTION DESCRIPTION 7 3 0 BASIC FUNCTIONING 7 4 0 OPERATING INSTRUCTIONS 8 5 0 CLEAN...

Page 4: ...14 5 368 37 940 546 21 5 765 30 13 394 15 5 368 14 5 STEAM SUPPLY 3 4 IPS 5 30 PSI 34 205 kPa OPTIONAL 5 45 PSI 34 310 KPa CONDENSATE RETURN 1 2 IPS 1512 1588 62 5 64 1626 1879 74 1930 76 59 5 K L 241...

Page 5: ...0 940 37 C 940 D E F G H K 303 litres 80 gallons 227 litres 60 gallons 28 710 840 33 42 5 1080 26 660 750 29 5 1029 40 5 STEAM SUPPLY 3 4 IPS 19MM 35 psi 2 4 KG CM 2 CONDENSATE RETURN IPS 13mm M N 2 J...

Page 6: ...ulfil NSF requirements 6 Connect steam line 3 4 pipe size to the kettle making sure there is a steam control valve strainer fairly convenient to the kettle 7 Connect kettle condensate return line to a...

Page 7: ...apacity of that kettle in U S gallons Thus a KLT 40DS is a two thirds jacketed direct steam kettle mounted on legs with a capacity of 40 gallons U S 3 2 FUNCTIONING MODE Blodgett direct connected stea...

Page 8: ...nt and its parts are hot Use care when operating cleaning and servicing Your kettle should be cleaned immediately after each use or when cooking a different product Before cleaning check that the kett...

Page 9: ...leak 3 Use a soft cloth or soft brush and clean all surfaces 4 Using both hands remove the valve from the soap and rinse well in another plastic pail that contains fresh water 5 Wash out the kettle as...

Page 10: ...oved by rubbing the surface with SCOTCH BRITE scouring pads or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further spoil the appearance of...

Page 11: ...uld be plumbed to the exit end of the kettle The thermostatic trap is a mechanical device that closes on high temperature and opens when the temperature drops allowing the water which formed from cond...

Page 12: ...12 that there is water in the jacket Open ball valve and drain Close valve and commence operation of kettle...

Reviews: