TROUBLESHOOTING
3---12
BC14G TIMER SETTINGS
Remove dial section
TOP VIEW
SIDE
VIEW
SIDE
VIEW
Inside if dial section
meter
A
B
C
D
Dial
L
R
A
) Top view of Timer.
NOTE: The
L
&
R
there are two timer adjustments per timer.
B
) Side view of timer.
C
) Side view with dial section removed. Carefully remove dial section with a pair of pliers.
D
) Inside of the dial section there are two terminals. Use your meter on the ohms setting.
Turn the dial until to the desired ohms value. Reattach the dial section and test unit.
1
2
3
4
1
2
3
4
FIGURE 10
T2 Steam duty cycle In combi mode.
L
) is 375K OHMS Steam
ON
45 seconds.
R
) is 666K OHMS Steam
OFF
80 seconds.
T3 One shot steam
NOTE: Set by timer on front panel.
T4 Flush timer
L
) Is 150K OHMS Flush
ON
90 seconds.
T5 Hot air duty cycle. In steam mode
.
L) is 375K OHMS Hot air ON 45 seconds
R) is 500K OHMS Hot air OFF 60 seconds
Summary of Contents for Combi BC14E
Page 4: ...BC14G INSTALLATION CHAPTER 1 ...
Page 12: ...OPERATION AND MAINTENANCE CHAPTER 2 ...
Page 16: ...BC14G TROUBLESHOOTING CHAPTER 3 ...
Page 29: ...BC14G SCHEMATICS CHAPTER 4 ...
Page 30: ...BC14G 4 1 BC14G FIGURE 1 ...
Page 31: ...SCHEMATICS 4 2 BC14G FOR CE FIGURE 1 ...
Page 32: ...BC14G 4 3 This page intentionally left blank ...
Page 33: ...PRE SITE VISIT QUESTIONS CHAPTER 5 ...
Page 36: ...BC14G AND BC14E 5 3 This page intentionally left blank ...
Page 37: ...COMPONENT IDENTIFICATION CHAPTER 6 ...
Page 44: ...BC14E SCHEMATICS CHAPTER 7 ...
Page 45: ...BC14E 7 1 BC14E FIGURE 1 ...
Page 46: ...TROUBLESHOOTING 7 2 BC14E FOR CE FIGURE 1 ...
Page 47: ...BC14E TROUBLESHOOTING CHAPTER 8 ...
Page 59: ...TROUBLESHOOTING 8 12 This page intentionally left blank ...
Page 60: ...BC14E INSTALLATION CHAPTER 9 ...