INSTALLATION
1---2
RATINGS -- GAS APPLIANCES -- BC14G/AA
Gas Type
Gas Input
Voltage
Phase
Amps
Motor
Natural
Steam --- 55,000 BTU/Hr
Hot Air
65 000 BTU/Hr
208-240
1
15
1/2HP 208-240VAC, 50/60 Hz
Hot Air --- 65,000 BTU/Hr
Total --- 115,000 BTU/Hr
120
1
15
1/2HP 208-240VAC, 50/60 Hz
Propane
Steam --- 48,000 BTU/Hr
Hot Air
65 000 BTU/Hr
208-240
1
15
1/2HP 208-240VAC, 50/60 Hz
Hot Air --- 65,000 BTU/Hr
Total --- 113,000 BTU/Hr
120
1
15
1/2HP 208-240VAC, 50/60 Hz
3/4” FNPT connector for all U.S. and Canadian installations
TABLE 4
RATINGS -- GAS APPLIANCES -- BC14GDS/AA
Gas Type
Gas Input
Voltage
Phase
Amps
Motor
Natural
65,000 BTU/Hr
208-240
1
15
1/2HP 208-240VAC, 50/60 Hz
120
1
15
1/2HP 208-240VAC, 50/60 Hz
Propane
65,000 BTU/Hr
208-240
1
15
1/2HP 208-240VAC, 50/60 Hz
120
1
15
1/2HP 208-240VAC, 50/60 Hz
3/4” FNPT connector for all U.S. and Canadian installations
TABLE 5
GAS PRESSURE -- BC14G/AA and BC14GDS/AA
Gas
T
Inlet
P
Orifice Size at Sea Level
Manifold Pressure
Type
Pressure
Hot Air
Steam
Hot Air
Steam
Natural
7---14” W.C.
.0531” dia
.042” dia
3.5” W.C.
3.5” W.C.
Propane
12---14” W.C.
.032” dia
.026” dia
10.0” W.C.
10.0” W.C.
TABLE 6
Summary of Contents for Combi BC14E
Page 4: ...BC14G INSTALLATION CHAPTER 1 ...
Page 12: ...OPERATION AND MAINTENANCE CHAPTER 2 ...
Page 16: ...BC14G TROUBLESHOOTING CHAPTER 3 ...
Page 29: ...BC14G SCHEMATICS CHAPTER 4 ...
Page 30: ...BC14G 4 1 BC14G FIGURE 1 ...
Page 31: ...SCHEMATICS 4 2 BC14G FOR CE FIGURE 1 ...
Page 32: ...BC14G 4 3 This page intentionally left blank ...
Page 33: ...PRE SITE VISIT QUESTIONS CHAPTER 5 ...
Page 36: ...BC14G AND BC14E 5 3 This page intentionally left blank ...
Page 37: ...COMPONENT IDENTIFICATION CHAPTER 6 ...
Page 44: ...BC14E SCHEMATICS CHAPTER 7 ...
Page 45: ...BC14E 7 1 BC14E FIGURE 1 ...
Page 46: ...TROUBLESHOOTING 7 2 BC14E FOR CE FIGURE 1 ...
Page 47: ...BC14E TROUBLESHOOTING CHAPTER 8 ...
Page 59: ...TROUBLESHOOTING 8 12 This page intentionally left blank ...
Page 60: ...BC14E INSTALLATION CHAPTER 9 ...