5
GENERAL
The gas boiler is designed to ASME Code and approved as a steam heating boiler
restricted to operation at pressure not to exceed 15 psi. The gas boiler may be in a 24"
cabinet base rated at 140,000 or 200,000 BTU, 36" cabinet base rated at 200,000,
250,000 or 300,000 BTU, operational on Natural or Propane gas. Boilers may have
optional electronic ignition and CSD1 controls.
1.0 INSTALLATION INSTRUCTIONS
UNPACKING
Immediately after unpacking, check for possible shipping damage. If the appliance is
found to be damaged, save the packaging material and contact the carrier within 15
days of delivery.
Before installing, verify that the gas (natural or propane), the elevation from sea level
and the electrical supply agree with the specification on the data plate. NOTE: If this
appliance is being installed above 2000 feet altitude, contact your authorized service
office to assure that the proper orifice size for your elevation has been installed.
LOCATION
The installation location must be kept free and clear of combustibles. Do not obstruct
the flow of combustion and ventilation air. Clearance from combustible construction
must be a minimum of 3 inches from the sides and 6 inches from the back. The
appliance should be installed on a noncombustible floor. Provide adequate clearances
for cleaning, maintenance, service and proper operation.
Sufficient air should be allowed to enter the room to compensate for the amount of air
removed by any ventilating system and for combustion of the gas burners. Do not
obstruct the air flow into and around the appliance. Do not obstruct the flow of flue
gases from the flue duct located at the rear and above the cabinet. Position the
appliance in its final location. Check that there are sufficient clearances to service the
controls, for door swings, etc., so there will be no problem in making the required supply
and drain connections.
Allow enough space between any other piece of equipment or a wall for service access.
Service on the cabinet base may require access to the left and/or right side panels.