PRESS
STORED FAULT CODES
PRESS
FUNC
d
0
1
Ÿ
keep pushing until
d
0
8
FUNC
once
E
?
?
Record Code
FUNC
once
d
0
8
Ÿ
keep pushing until
d
0
9
FUNC
once
E
?
?
Record Code
FUNC
once
d
0
9
ź
keep pushing until
d
0
1
FUNC
once
0.
0
COMPLETED
Motor Inverter Error Codes
E_01
Over current event while at constant speed
E_02
Over current event during deceleration
E_03
Over current event during acceleration
E_04
Over current event during other conditions
E_05
Overload protection
E_07
Over-voltage protection
E_08
EEPROM error
E_09
Under-voltage error
E_11
CPU error
E_22
CPU error
E_12
External trip
E_13
USP
E_14
Groung Fault
E_15
Input over-voltage
E_21
Inverter thermal trip
E_35
Thermistor