Delime and Flush sequence for BCX14
&XUHQW
Manual & Menuselect:
DELIME
Delime
Step
Function
Temp
Time / Trigger
1
Fill the boiler
Emptying the boiler
Fill the boiler
Emptying the boiler
Pre-fill the boiler
Water at High Level
90 sec (0 - 300 range)
Water at High Level
90 sec (0 - 300 range)
10 sec (0 - 300 range)
2
Pumping delime chemical into boiler
Delime solution detection
80 sec (0 - 300 range)
Water(Solution) at High Level
3
Wait so level sensor is dry
Filling
Overfill
30 sec -(0 - 300 range) No Water
Low Level
Water at High Level
5 sec (0 - 300 range)
4
Heating up
110°F(32 -250) N/A
5
Pause
3 min (0 - 300 range)
6
Heating up
140°F(32 -250) N/A
7
Pause
3 min (0 - 300 range)
8
Heating up to 185°F,
and let cool down to 180°F and back
to heating
140°F(32 -250) 30 min (0 - 300 range)
9
Fill the boiler
Emptying the boiler
Filling
Overfill
Water at High Level
90 sec (0 - 300 range)
High Level
10 sec (0 - 300 range)
10
Rinse 1/3 – Empty
Rinse 1/3 - Fill
Overfill for 10 sec
90 sec (0 - 300 range)
Water at High Level
10 sec (0 - 300 range)
11
Rinse 2/3 – Empty
Rinse 2/3 – Fill
90 sec (0 - 300 range)
Water at High Level
12
Heating up
140°F(32 -250) Setpoint
13
Boiling for 2 min
Pause
120 sec (0 - 300 range)
30 sec (0 - 300 range)
14
Rinse 3/3 – Empty
Rinse 3/3 - Fill
90 sec (0 - 300 range)
Water at High Level
FLUSH
Flush
Step
Function
Temp
Time / Trigger
1
Fill the boiler
Emptying the boiler
Filling Overfill
Water at High Level
90 sec (0 - 300 range)
High Level 10 sec (0 - 300 range)
2
Rinse 1/3 – Empty
Rinse 1/3 - Fill
Overfill for 10 sec
90 sec (0 - 300 range)
Water at High Level
10 sec (0 - 300 range)
3
Rinse 2/3 – Empty
Rinse 2/3 – Fill
90 sec (0 - 300 range)
Water at High Level
4
Heating up
140°F(32 -250) Setpoint
5
Heat for 2 min
Pause
140°F(32 -250) 120 sec (0 - 300 range)
30 sec (0 - 300 range)
6
Rinse 3/3 – Empty
Rinse 3/3 - Fill
90 sec (0 - 300 range)
Water at High Level
17
Summary of Contents for BCX-14G
Page 65: ...EŽƚĞƐ 65 ...
Page 68: ...1 68 ...
Page 70: ...3 70 ...
Page 71: ...4 71 ...
Page 72: ...5 72 ...
Page 73: ...6 73 ...
Page 74: ...7 74 ...
Page 75: ...8 I 75 ...
Page 76: ...9 y I i w II VA w ti m dul will non 76 ...
Page 78: ...11 If t r t n 4 th modul 100 nd th pll t r m lnln 78 ...
Page 84: ...50 0 235 Volts AC 3Ø 2 7 Amps Forward 84 ...
Page 85: ...50 0 235 Volts AC 3Ø 2 7 Amps Reverse 85 ...
Page 109: ...EŽƚĞƐ 109 ...
Page 112: ...112 ...
Page 113: ...113 ...