Installation
9
Electrical Connections
Before making any electrical connections to these
units, check that the power supply is adequate for
the voltage, amperage, and phase requirements
stated on the rating name plate mounted on the
right side of the unit.
Wiring diagrams are located on the inside of the
removable side panel.
NOTE: DISCONNECT THE POWER SUPPLY TO
THE UNIT BEFORE SERVICING!
U.S. and Canadian installation
All units, when installed, must be electrically
grounded in accordance with local codes or in the
absence of local codes, with the
National Electrical
Code, ANSI/NFPA 70-Latest Edition and/or CanaĆ
dian Electrical Code CSA C22.1
as applicable.
General Export Installations
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installation and/or
operation of your unit, please contact your local
distributor. If you do not have a local distributor,
please call Blodgett Combi at 0011Ć802Ć860Ć3700.
WARNING!!
Improper electrical installation will invaliĆ
date your warranty.
Gas Models
U.S. and Canadian Installations
A power cord (115V or 230V) is supplied with a
plug attached. Plug the power cord into the deĆ
sired receptacle.
This oven model uses a variable frequency invertĆ
er drive. Appliances that use variable frequency
inverter drives produce high frequency noise and
require filters and shielded motor cabling. This
causes higher leakage current toward Earth
Ground. Especially, at the moment of switching
ON this can cause an inadvertent trip of the apĆ
pliance's ground fault interrupter (GFCI). Some
GFCIs are more sensitive than others. Blodgett
has qualified the Pass and Seymour brand, part
number 2095, 20 A, 125 VAC, 60 Hz, specification
grade GFCI duplex receptacle as being immune to
the variable frequency inverter drive's noise. BlodĆ
gett recommends using this specific GFCI for this
model oven.
WARNING!!
If the supply cord is damaged, it must be
replaced by a special cord or assembly
available from the manufacturer or its serĆ
vice agent.