Installation
8
Plumbing Connections
WATER CONNECTION
NOTE: Hot water maximizes steam production
but is not required. Cold water may be
supplied to both inlets if hot water is not
available.
BCĆ20G
- Connect the appliance to quality cold
water via a pressure hose with 3/4" (1/9 cm) couĆ
plings. Cold water is connected to the left solenoid/
pressure regulator as viewed from the rear of the
oven. Hot water connection, right solenoid/pressure
regulator, to the boiler is recommended. A shut off
valve must be provided adjacent to the oven.
NOTE: Hot water must not be applied to the cold
water inlet.
1/2" Appliance Hose
With 3/4" Hose Fittings
Figure 2
WARNING!!
The use of poor quality water will invaliĆ
date your warranty.
This product must be installed by a licensed
Plumber or Gas Fitter when installed within the
Commonwealth of Massachusetts.
DRAIN CONNECTION
A 2" (5 cm) copper pipe with standard drain pitch
must be run to an open drain or connected to a
standpipe equipped with a vent.
NOTE: The waste water can also be directed to a
nearby floor drain. Flexible hose which alĆ
lows trapped water to accumulate in
sagged runs must be avoided.
1. Find the drain connection on the lower rear of
the unit.
2. Loosen the coupling clamps. Attach a 2" (5
cm) copper drain pipe to the drain connection.
Retighten the coupling clamps.
NOTE: The open end of the drain should be inĆ
stalled facing the floor. Copper line, used
for installation to an open drain or floor
sink, must be supplied by the installer.
Use
of a trap inline will cause drain backup.
2" Drain
Customer
Supplied
To Drain
Oven
Drain
Figure 3
Specific water/drain connection for City of Los
Angeles
1. Each drain line from the appliance shall be
routed without dips or sags to terminate above
the flood level rim of an approved indirect waste
receptor.
2. The appliance shall be installed in accordance
with the manufacturer's printed instructions
and the LAPC and LAMC, 1999 editions.
3. A backflow protection device may be required
by local codes. If so, install on the potable water
system directly ahead of the appliance. The
backflow protection device shall be any of the
following: an approved pressure type vacuum
breaker installed at least 12" above the highest
point of use, a double check valve backflow preĆ
venter or a reduced pressure principal backflow
preventer.