background image

OM-KPT/KLT-DS

The Blodgett KLT/KPT series are deep type, tilting kettles with direct steam-heated 2/3 
jackets. The stainless steel kettles have welded, reinforced rims and butterfly shaped 
pouring lips. The liner and pouring lip of all kettles are 316 stainless steel. They are 
ASME shop-inspected, and are registered with the National Board. The kettles have a 
180 emery grit interior finish and a bright semi-deluxe exterior finish.

Every unit requires a remote steam source. The steam supply is controlled by an inlet 
valve, and enters the jacket through one trunnion directly into the jacket. Steam pressure 
forces condensate out a dip tube through the other trunnion. Both steam and condensate 
lines are concealed within the support structures of the various models. The tale at 
bottom right shows the standard kettle sizes for each model.

These kettles operate safely and efficiently at various steam pressures above five PSI, 
with upper pressure limits assured by the provided safety valve. Operation also requires 
a globe valve on the steam inlet and a strainer, steam trap, and check valve on the 
condensate outlet. These may be ordered as optional equipment.

Kettles are emptied by tilting, but optional tangent draw-offs are available. The
standard draw-off is two inch outer diameter stainless steel, with compression disc 
valve and a removable stainless steel strainer that has 1/4 inch perforations. Strainers 
with 1/8 inch or no perforations are also available. The table on the bottom right shows 
the sizes of draw-offs which can be furnished with each model.

The kettles in this series employ a worm and gear tilting mechanism, which is 
completely enclosed.

The kettles are mounted in two ways. The KPT Model is suspended in a stainless steel 
yoke on a pedestal base. The outer circumference of the base is flanged down for proper 
sealing to the floor. The KLT Model is supported by a tubular, stainless steel tri-leg frame 
with adjustable floor flanges. 

Options include:
1.   Lift-off cover (for kettles smaller than 60 gallons)
2.   Cover with counter-balancing actuator (for 40 gallon and larger kettles)
3.   Fill faucets with swing spout
4.   Basket cooking system
5.   Kettle brush kit
6.   Operating pressures up to 90 PSIG 

Equipment Description

Summary of Contents for 20DS-KLT

Page 1: ...w blodgett com 44 Lakeside Avenue Burlington Vermont 05401 USA Manufacture Service Questions 866 518 3977 PART NUMBER 170099 REV B 04 11 KPT KLT DS Series DIRECT STEAM TILTING FLOOR KETTLE INSTALLATIO...

Page 2: ...erty damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibil...

Page 3: ...E DO NOT STAND DIRECTLY IN FRONT OF KETTLE BODIES WHEN THEY ARE BEING TILTED WARNING AVOID ALL DIRECT CONTACT WITH HOT EQUIPMENT SURFACES DIRECT SKIN CONTACT COULD RESULT IN SEVERE BURNS WARNING AVOID...

Page 4: ...READ AND FOLLOW ALL PRECAUTIONS STATED ON THE LABEL OF THE WATER TREATMENT COMPOUND CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN EYES MUCOUS MEMBRANES AND CLOTHING PRECAUTIONS SHOULD BE TAKEN WEAR RU...

Page 5: ...10 Maintenance page 11 Cleaning page 12 13 Troubleshooting page 14 Parts List page 15 Bucket Steam Trap page 16 Service Log page 17 KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Pau Minnesota 55102...

Page 6: ...a globe valve on the steam inlet and a strainer steam trap and check valve on the condensate outlet These may be ordered as optional equipment Kettles are emptied by tilting but optional tangent draw...

Page 7: ...PT 60 Gallons 225 liters 30 inches 762 mm 43 inches 1092 mm 47 inches 1194 mm 34 inches 864 mm Yoke Pedestal 20DS KLT 20 Gallons 75 liters 20 inches 508 mm 36 inches 914 mm 36 1 4 inches 921 mm 29 inc...

Page 8: ...ation for future reference Space for these entries is provided at the top of the Service Log in the back of this manual When installation is to begin cut the straps holding the unit on the skid Lift t...

Page 9: ...the kettle condensate return line to the boiler return line or to a drain A suitable steam trap strainer and check valve must be installed 7 Any mechanical change must be approved by the Food Service...

Page 10: ...enough to let steam escape Then let it snap back into place to reseat the valve so that it will not leak 6 Shut down the unit by closing the steam inlet valve 7 Operate the tilting mechanism and draw...

Page 11: ...d its position when you stop turning the wheel If the tilting mechanism seems to be locked do not use force to free the kettle Call for assistance from a Certified Service Agency or refer to the Troub...

Page 12: ...boiler system or by the pressure reducing valve which serves the kettle In the jacket steam releases its heat to the kettle as it condenses into water The steam trap allows condensate water to leave...

Page 13: ...the valve leaks immediately discontinue use of the kettle and contact a qualified service representative 2 At least once every 90 days inspect fittings and valves for signs of damage or wear Regularl...

Page 14: ...as the underside of the cover 9 To remove burned on materials use a brush sponge cloth plastic or rubber scraper or plastic wool with the cleaning solution To reduce effort required in washing let th...

Page 15: ...ce of equipment be sanitized just before use 14 If there is difficulty removing mineral deposits or a film left by hard water or food residues clean the kettle thoroughly and use a deliming agent in a...

Page 16: ...leaks a small amount of steam User a For contamination that prevents seating the valve With substantial pressure in the jacket lift the valve lever briefly all the way up to blow the valve clean then...

Page 17: ...13 WORM 12026 14 SHAFT 003129 15 HANDWHEEL WITH HANDLE 139152 16 HANDWHEEL SHAFT 003130 17 COLLAR 137246 18 GREASE FITTING 45 DEG 012099 19 CASTING TRUNNION RACE 012113 20 DRAW OFF VALVE 2 COMPLETE 00...

Page 18: ...SE NIPPLE 3 008877 4 FEMALE UNION 1 004186 5 BUCKET STEAM TRAP 1 004183 6 SWING CHECK VALVE 1 004187 7 GLOBE VALVE 1 004222 8 CLOSE NIPPLE 2 008238 9 FEMALE UNION 1 005516 10 90 STREET ELBOW 1 008347...

Page 19: ...OM KPT KLT DS 17 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Service Performed Performed By...

Page 20: ...PART NUMBER 170099 REV B 04 11 BLODGETT OVEN COMPANY www blodgett com 44 Lakeside Avenue Burlington Vermont 05401 USA Telephone 866 518 3977...

Reviews: