Installation
9
Utility Connections
WATER CONNECTION
The oven requires access to potable water with an
inlet pressure of approximately 40 to 50 PSI.
1. The water is connected to the rear of the instalĆ
lation base at the 3/4" NPT female coupling.
Figure 4
2. The water is directed to the oven through an
inĆline pressure regulator and a flexible interĆ
nal hose which connects to a fitting in the front
of the oven. (Set at 35 psi.)
Connect
Hose Here
Figure 5
DRAIN CONNECTION
The unit is provided with an optional wrotĆcopper
soldered end tube fitting reducer 3" x 2" funnel that
may be fixed to the installation base. For multiple
oven installations, install a deck mounted sloping
drain with individual funnels positioned to accept
the drain outlets of the individual ovens.
The power requirement of the oven is 440 volt, 3
phase, 60 amp service.
1. The electrical service is brought into the oven
through the seal tight connector located on
the rear of the installation base.
2. The power leads are brought into a water
proof terminal box located in the front of the
installation base.
3. A grounding stud is supplied on the inside of
the installation base. See Figure 6.
Figure 6