3. SETUP

Fuse Replacement

CAUTION!  The SnowBlind™ utilizes a high-output switch-mode power 

supply with an internal fuse.  Under normal operating conditions, the fuse 

should not require replacement.  The fuse is field replaceable, however 

it is an advanced procedure suited to qualified individuals.  Should your 

SnowBlind™ fuse require replacement, please contact Blizzard Lighting for 

instructions, or to return your unit for service.

Connecting A Bunch of SnowBlind™ Fixtures

You will need a serial data link to run light shows using a DMX-512 

controller or to run shows on two or more fixtures set to sync in master/

slave operating mode. The combined number of channels required by all 

the fixtures on a serial data link determines the number of fixtures the 

data link can support.

Fixtures on a serial data link must be daisy chained in one single line. 

Also, connecting more than 32 fixtures on one serial data link without the 

use of a DMX optically-isolated splitter may result in deterioration of the 

digital DMX signal. The maximum recommended cable-run distance is 500 

meters (1640 ft).  The maximum recommended number of fixtures on a 

serial data link is 32 fixtures.

Data/DMX Cabling

To link fixtures together you’ll need data cables.  You should use data-

grade cables that can carry a high quality signal and are less prone to 

electromagnetic interference.

For instance, Belden© 9841 meets the specifications for EIA RS-485 

applications. Standard microphone cables will “probably” be OK, but note 

that they cannot transmit DMX data as reliably over long distances.  In 

any event, the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

Summary of Contents for snowblind

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2012...

Page 2: ...owBlind Pin up Picture 6 Rear Connections 6 3 Setup 7 Fuse Replacement 7 Connecting A Bunch Of SnowBlind s 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up...

Page 3: ...the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your...

Page 4: ...me fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event...

Page 5: ...easy to use LED control panel menu Aluminum mounting bracket with locking knobs Lightweight and Compact It kept its New Years resolution The SnowBlind is a great little LED strobe fixture that packs...

Page 6: ...Lighting LLC Figure 1 The SnowBlind Pin Up Picture 18x 1 Watt Cool White LED s Aluminum Housing LED Control Panel Figure 2 The Rear Connections AC Power In 3 Pin DMX512 In 3 Pin DMX512 Out Mounting Br...

Page 7: ...s on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deteri...

Page 8: ...d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used N...

Page 9: ...y the fixtures that follow may also require a slave setting Check the Operating Adjustments section in this manual for complete instructions for this type of setup and configuration Mounting Rigging T...

Page 10: ...g order The Control Panel LED Display shows the menu items listed on the Control Panel Menu Structure below Pushing the MODE button repeatedly will scroll through the menu settings To edit one push th...

Page 11: ...ck to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable Chase Speed Too Fast Slow Check to ensure proper setup of speed adjustment No Power Check fuse AC cord a...

Page 12: ...mer levels You can think of it as 512 faders on a lighting console connected to 512 light bulbs Each slider s position is sent over the data link as an 8 bit number having a value between 0 and 255 Th...

Page 13: ...to 512 bytes of data Data pack ets are transmitted continuously As soon as one packet is finished another can begin with no delay if desired usually another follows within 1 ms If nothing is changing...

Page 14: ...atisfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a...

Page 15: ...ion 25W Light Source LED 18x 1 Watt LED s Cool White 100 000 hours Optical Beam Angle 15 degrees Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channe...

Page 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: