Blizzard snowblind User Manual Download Page 12

Page 12

SnowBlind™ Manual - Rev. A  

 

 

Copyright (c) 2012 Blizzard Lighting, LLC

5. APPENDIX

A Quick Lesson On DMX

DMX (aka DMX-512) was created in 1986 by the United States Institute for 
Theatre Technology (USITT) as a standardized method for connecting lighting 
consoles to lighting dimmer modules. It was revised in 1990 and again in 2000 

to allow more flexibility.  The Entertainment Services and Technology Associa

-

tion (ESTA) has since assumed control over the DMX512 standard.  It has also 
been approved and recognized for ANSI standard classification.  

DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the 
most common communications standard used by lighting and related stage 

equipment.  

DMX provides up to 512 control “channels” per data link. Each of these chan

-

nels was originally intended to control lamp dimmer levels. You can think of it 

as 512 faders on a lighting console, connected to 512 light bulbs. Each slider’s 

position is sent over the data link as an 8-bit number having a value between 
0 and 255. The value 0 corresponds to the light bulb being completely off while 
255 corresponds to the light bulb being fully on. 

DMX data is transmitted at 250,000 bits per second using the RS-485 trans-
mission standard over two wires. As with microphone cables, a grounded cable 
shield is used to prevent interference with other signals.

There are five pins on a DMX connector: a wire for ground (cable shield), two 

wires for “Primary” communication which goes from a DMX source to a DMX re-
ceiver, and two wires for a “Secondary” communication which goes from a DMX 
receiver back to a DMX source. Generally, the “Secondary” channel is not used 

so data flows only from sources to receivers.  Hence, most of us are most famil

-

iar with DMX-512 as being employer over typical 3-pin “mic cables,” although 

this does not conform to the defined standard.

Summary of Contents for snowblind

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2012...

Page 2: ...owBlind Pin up Picture 6 Rear Connections 6 3 Setup 7 Fuse Replacement 7 Connecting A Bunch Of SnowBlind s 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up...

Page 3: ...the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your...

Page 4: ...me fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event...

Page 5: ...easy to use LED control panel menu Aluminum mounting bracket with locking knobs Lightweight and Compact It kept its New Years resolution The SnowBlind is a great little LED strobe fixture that packs...

Page 6: ...Lighting LLC Figure 1 The SnowBlind Pin Up Picture 18x 1 Watt Cool White LED s Aluminum Housing LED Control Panel Figure 2 The Rear Connections AC Power In 3 Pin DMX512 In 3 Pin DMX512 Out Mounting Br...

Page 7: ...s on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deteri...

Page 8: ...d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used N...

Page 9: ...y the fixtures that follow may also require a slave setting Check the Operating Adjustments section in this manual for complete instructions for this type of setup and configuration Mounting Rigging T...

Page 10: ...g order The Control Panel LED Display shows the menu items listed on the Control Panel Menu Structure below Pushing the MODE button repeatedly will scroll through the menu settings To edit one push th...

Page 11: ...ck to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable Chase Speed Too Fast Slow Check to ensure proper setup of speed adjustment No Power Check fuse AC cord a...

Page 12: ...mer levels You can think of it as 512 faders on a lighting console connected to 512 light bulbs Each slider s position is sent over the data link as an 8 bit number having a value between 0 and 255 Th...

Page 13: ...to 512 bytes of data Data pack ets are transmitted continuously As soon as one packet is finished another can begin with no delay if desired usually another follows within 1 ms If nothing is changing...

Page 14: ...atisfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a...

Page 15: ...ion 25W Light Source LED 18x 1 Watt LED s Cool White 100 000 hours Optical Beam Angle 15 degrees Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channe...

Page 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: