This unit is a rugged, tough piece of professional equipment, and as long as you take 

care of it, it will take care of you. That said, like anything, you’ll need to take care of 

it if you want it to operate as designed.  You should absolutely keep the fixture clean, 

especially if you are using it in an environment with a lot of dust, haze, wild animals, 

wild teenagers or spilled drinks.  

Cleaning Instructions:

1.) You should follow these instructions after approximately 40 hours of use.

2.) Take off the fluid nozzle before heating the machine, and clean the nozzle with 

straight vinegar.

3.) To clean the fluid tank, pour in and run a solution of 80% distilled water and 20% 

white vinegar through the machine. When empty turn off the machine.

4.) Wait for it to cool down, re-install the nozzle, and you can now add more fluid to 

prepare for its next use.

Returns (Gasp!)

We’ve taken a lot of precautions to make sure you never even have to worry about 

sending a defective unit back, or sending a unit in for service.  But, like any complex 

piece of equipment designed and built by humans, once in a while, something 

doesn’t go as planned.  If you find yourself with a fixture that isn’t behaving like a 

good little fixture should, you’ll need to obtain a Return Authorization (RA).  

Don’t worry, this is easy. Just go to our website and open a support ticket at

www.blizzardlighting.com/support, and we’ll issue you an RA. Then, you’ll need to 

send the unit to us using a trackable, pre-paid freight method.  We suggest using 

USPS Priority or UPS.  Make sure you carefully pack the fixture for transit, and 

whenever possible, use the original box & packing for shipping.

When returning your fixture for service, be sure to include the following:

 

1.) Your contact information (Name, Address, Phone Number, Email address).

 

2.) The RA# issued to you

 

3.) A brief description of the problem/symptoms.

We will, at our discretion, repair or replace the fixture.  Please remember 

that any shipping damage which occurs in transit to us is the customer’s 

responsibility, so pack it well!

Shipping Issues

Damage incurred in shipping is the responsibility of the shipper, 

and must be reported to the carrier immediately upon receipt of 

the items.  Claims must be made within seven (7) days of receipt.

Summary of Contents for AtmosFEAR Big Bad Lo Fo

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2018...

Page 2: ...heostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Please verify that the unit is suitable for your local power supply See the unit s specifications for more information The lis...

Page 3: ...s Be sure that no air intake slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type DO NOT operate at ambient...

Page 4: ...you can add any type of water based fog liquid light standard heavy etc in order to give on the effect different dimension intensity and duration MAIN FEATURES DMX controllable water based low lying...

Page 5: ...rd Lighting s own Steam fog fluid products Step 3 Fill the water tank manually or via the water inlet connection Step 4 Connect the hoses to the output ducts Step 5 Connect the machine to suitable rat...

Page 6: ...e the water tank Note When filling the tank the water level needs to be covering the water level sensors by at least about 3 4 cm If there is not enough water in the tank the red warning LED near the...

Page 7: ...ated splitter may result in deterioration of the digital DMX signal The maximum recom mended cable run distance is 500 meters 1640 ft Data DMX Cabling To link units together you ll need data cables Yo...

Page 8: ...gher level menu item Value adjustment upward Value adjustment downward Is used to select and confirm store the current selection Starts or stops timer operation To navigate the control menu use the ME...

Page 9: ...ime in between timed fog outputs in sec onds while duration settings are used to control the actual period of time of the timed output in seconds while using timer mode 1 Press the MENU button repeate...

Page 10: ...it back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that i...

Page 11: ...r Consumption 1983W 19 1A PF 99 Fuse 15A 250V Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Operation Capacity Warm up Time 5 8 min Water Tank Capacity 13L Fluid Tank Capacity 2L Outpu...

Page 12: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: