background image

Page 15

Flurry Spot Manual Rev. A  

 

 

Copyright (c) 2010 Blizzard Lighting, LLC

DMX Channel Values (5 Channel Mode)

Channel

Channel Value

Does...

1

000 <-> 255

Pan

2

000 <-> 255

Tilt

3

000 <-> 007

008 <-> 134

135 <-> 239

240 <-> 255

Dimmer/Strobe

Closed

100%-0% Dimming

Strobe (Slow-Fast)

Open

4

000 <-> 007

008 <-> 021

022 <-> 035

036 <-> 049

050 <-> 063

064 <-> 077

078 <-> 091

092 <-> 105

106 <-> 119

120 <-> 133

134 <-> 147

148 <-> 161

162 <-> 175

176 <-> 189

190 <-> 203

204 <-> 217

218 <-> 231

232 <-> 244

245 <-> 255

Color Macros

No Function

White

Red

Green

Blue

Cyan

Magenta

Yellow

Orange

Purple

Pink

Light Blue

Aqua

Chartreuse

Light Blue

Light Pink

Light Purple

Color Change Macro #1

Color Change Macro #2

5

Gobo (Pattern) Select

080 <--> 214 - Gobo Shake (Slow <--> Fast)

215 <--> 255 - Gobo Wheel Spin

(Clockwise <--> Counterclockwise, Slow <--> Fast)

000<-->007

008<-->015

016<-->023

024<-->031

032<-->039

040<-->047 048<-->055

056<-->063

064<-->071

072<-->079

Page 16

Flurry Spot Manual Rev. A  

 

 

Copyright (c) 2010 Blizzard Lighting, LLC

Troubleshooting

Symptom

Solution

Fixture Auto-

Shut Off

Check the fan in the fi xture.  If it is stopped or moving 

slower than normal, the unit may have shut itself off due to 

high heat.  This is to protect the fi xture from overheating.  

Clear the fan of obstructions, or return the unit for service.

Beam is Dim

Check optical system and clean excess dust/grime.  Also 

ensure that the 220V/110V switch is in the correct position, 

if applicable.

No Light Output Check to ensure fi xture is operating under correct mode, IE 

sound active/auto/DMX/Etc., if applicable.  Contact service 

for more information.

Chase Speed 

Too Fast/Slow

Check to ensure proper setup of speed adjustment.

No Power

Check fuse, AC cord and circuit for malfunction.

Blown Fuse

Check AC cord and circuit for damage, verify that moving 

parts are not restricted and that unit’s ventilation is not 

obstructed.

Slow Movement Verify that 220V/110V switch is in the correct position, if 

applicable.  Also check that speed channels are set appropri-

ately.

No Response to 

Audio

Verify that the fi xture is in “Sound Active” mode.

Adjust Audio Sensitivity, If Applicable.

Fixture Not 

Responding / 

Responding Er-

raticly

Make sure all connectors are seated properly and securely.

Use Only DMX Cables.

Install a Terminator.

Check all cables for defects.

Reset fi xture(s).

Intermittant 

Lamp

Check lamp for properly installation.

Relamp, lamp may have reached end of life.

Remote Doesn’t 

Work

Verify remote control cable is installed properly and securely. 

Verify remote is correct type (CA-9 or other as applicable.)

Fixture Moving 

On Its Own

Verify proper mode of operation.  Is the fi xture in “Auto” 

mode?

If your problem isn’t listed, or if problems persist, 

please contact support:  [email protected].

Summary of Contents for Flurry Spot

Page 1: ...Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 The Control Panel 10 Control Panel Menu Structure 11 Additional User Adjustments 12 Setting the pan tilt Menu to inverting or non inverting 12 Setting the DMX channel configuration 12 Setting the maximum pan angle 12 Setting the maximum...

Page 2: ...s If something is wrong just give us a call or send an email We ll be happy to help honest Blizzard Lighting 2705 Brookview Ct Brookfield WI 53005 USA support blizzardlighting com www blizzardlighting com Page 4 Flurry Spot Manual Rev A Copyright c 2010 Blizzard Lighting LLC SAFETY INSTRUCTIONS Please keep this User Guide for future use If you sell the unit to someone else be sure that they also r...

Page 3: ...pt its new year s resolution LED display menu with invert Reset to factory settings option Display auto on off Pan tilt invert option Fan cooled OPTIONAL CONTROLLERS Easy Controller CA 9 DMX Quick Reference 13 Channel Mode Channel What It Does 1 Pan 2 Tilt 3 Pan Fine 16 Bit 4 Tilt Fine 16 Bit 5 Pan Tilt Speed 6 Dimmer Strobe 7 Red Intesity 8 Green Intensity 9 Blue Intensity 10 Color Macros 11 Colo...

Page 4: ...citance between conductors 30 pF ft Maximum capacitance between conductor shield 55 pF ft Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms Page 8 Flurry Spot Manual Rev A Copyright c 2010 Blizzard Lighting LLC Cable Connectors Cables must have a male XLR connector on one end and a female XLR connector on the other end Duh CAUTION Do not allow contact between the common and the ...

Page 5: ...lting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration lamp replacement access if applicable and routine maintenance Safety cables MUST ALWAYS be used Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Page 10 Flurry Spot Manual Rev A Copy...

Page 6: ...e the UP DOWN buttons to set to the desired position press ENTER to confirm TO SET THE DMX CHANNEL CONFIGURATION 1 Press the MODE ESC button until it shows or 2 Use the UP DOWN buttons to set to the desired position press ENTER to confirm TO SET THE MAXIMUM PAN ANGLE 1 Press the MODE ESC button until it shows or or 2 Use the UP DOWN buttons to set to the desired position press ENTER to confirm TO ...

Page 7: ...e Off Mode 1st click Sound Active Mode Remote LED will be on 2nd click Auto Mode LED will be off DMX Mode Allows the unit to be controlled by any universal DMX controller If you are unfamiliar with DMX please read the DMX Primer on page 17 1 The default mode for the fixture is DMX which appears as on the LED Readout Page 14 Flurry Spot Manual Rev A Copyright c 2010 Blizzard Lighting LLC DMX Channe...

Page 8: ...d clean excess dust grime Also ensure that the 220V 110V switch is in the correct position if applicable No Light Output Check to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable Contact service for more information Chase Speed Too Fast Slow Check to ensure proper setup of speed adjustment No Power Check fuse AC cord and circuit for malfunction Blown Fuse C...

Page 9: ... be output per packet and in fact it is very uncommon to find all 512 used The fewer channels are used the higher the refresh rate It is possible to get DMX refreshes at around 1000 times per second if only 24 channels are being transmitted If all 512 channels are being transmitted the refresh rate is around 44 times per second In summary since its design and evolution in the 1980 s DMX has become...

Page 10: ...V Power Consumption 120W Light Source LED 1x15W RGB 100 000 hours Movement Range Pan 540 degrees Tilt 270 degrees Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 5 or 13 User Selectable Input 3 pin XLR Male Output 3 pin XLR Female Optional Controller CA 9 Easy Controller Coolness Factor Leventy Billion Percent Warranty 2 year limited warran...

Reviews: