YOU SHOULD HAVE

VALANCE CLIP

Hook the valance clips evenly along 

the length of the headrail, prior to 

installing the blind in the brackets.

HOLD DOWN BRACKET

Hold down brackets using two small 

screws, screw hold down bracket to 

window facing or wall. 

Snap bracket pin ends into the hole at 

bottom rail end.

(OPTIONAL)

X2

Engage the top leg of the valance 

clip into the groove on the back of 

the valance. Then push the valance 

towards the headrail to engage the 

bottom leg.

HOLD DOWN BRACKET

(OPTIONAL)

If your blind has been supplied with 

valance returns slide the valance 

return clip onto the valance. Slot the 

other end of the valance clip onto the 

valance return and align the edge.

FITTING THE HEADRAIL

ATTACHING THE VALANCE 

INSTALLING CHILD SAFETY DEVICE 

SAFETY DEVICE 

Cord safety cleat

 - The safety cleat 

shall be installed as close to the 

headrail as possible and in all cases not 

less than 1500mm from the floor.

The Cord must be fully accumulated 

around the safety cleat(s) when the 

blind is not in use. 

Use the table below to determine the 

distance required between the cleats 

to fully accumulate the cords when the 

blind is fully raised.

Place the safety cleat in the desired 

position on the wall and mark the 

positions of the holes with a pencil.

(Note: Based on cord up to 2.8mm, 

17m can be accumulated in total.)

(Note: Based on cord up to 2.8mm, 

17m can be accumulated in total.)

* Distance 

 between

 cord cleats

Use the screws provided to attach the 

safety cleat to the wall..

X2

Wrap the cords around the cord cleats 

in a figure of 8. When the cords are 

fully accumulated ensure they are 

secure so when any cord is pulled no 

excess cord is released.

THE INSTALLATION HEIGHT OF THIS BLIND MUST NOT BE LESS THAN 

1500MM FROM THE FLOOR.

FITTING THE BOX BRACKETS 

OUTSIDE RECESS

If the blind is to be fitted outside 

the window ensure that measure-

ment C is the same. Follow instruc-

tions for FACE FIXING. To calculate 
C=(A-B)/2.

 

INSIDE RECESS 

TOP FIX to the lintel or FACE FIX 

brackets to the window frame.

(A) Width of Blind

(B) Top Fix

(C)

(C)

TOP FIXING 

Measure & mark the distance 

between the wall & the back of the 

bracket, allowing for obstructions 

like handles that protrude into the 

recess area. The brackets should 

be positioned 6mm wider than 

the blind at each end. Hold each 

bracket into place and mark the 

hole positions. Fit each bracket 

using the screws provided. Please 

ensure fixings are suitable for the 

wall/surface to which you are 

mounting the brackets.

FACE FIXING

The brackets should be positioned 

6mm wider than the blind at each end. 

Hold each bracket into place and mark 

the hole positions. Fit each bracket 

using the screws provided. Please 

ensure fixings are suitable for the wall/

surface to which you are mounting the 

brackets

SIDE FIXING

CENTRE SUPPORT BRACKET

For larger width blinds a centre  

support bracket is required. 

Align the top of the centre support 

bracket with the top of the mounting 

bracket before installation. 

Install with the bigger flap of the 

centre support bracket on the top 

equally spaced along the width of the 

headrail and clear of the slat 

ladder positions.

CHILDREN CAN STRANGLE IF A 

SAFETY DEVICE IS NOT INSTALLED. 

ALWAYS USE A SAFETY DEVICE  TO 

KEEP CORDS AND CHAINS OUT OF 

REACH  OF CHILDREN.

Hold each bracket into place and mark 

the hole positions. Fit each bracket 

using the screws provided. Please 

ensure fixings are suitable for the wall/

surface to which you are mounting the 

brackets.

TOOLS REQUIRED

•  Screwdriver

•  Pencil

•  Power-Drill

•  Tape Measure

BRACKETS

SAFETY DEVICE

WOOD SCREWS 

(2 per bracket)

 

VALANCE & RETURN CLIPS

HOLD-DOWN BRACKET 

(x2)

•    2 screws for safety cleat

•    4 small screws for hold down brackets 

     (2 per bracket)

Open the gate of the box brackets and 

slide the headrail into position then 

snap the brackets closed.

Number of 

ladders

brackets

Centre support

brackets

(supplied)

0

1

1

2

3

3

4

2

3

4

5

6

7

8

9

2

2

2

2

2

2

2

2

4

Drop of Blind

*Distance between 

cord cleats (centre 

to centre)

1-1000mm

100mm

1001-2000mm

150mm

2001-3000mm

300mm

Reviews: